Table 14: General system data
Minimum
Typical
Maximum
Weight (without packaging)
–
0.18 kg
–
Electrical Safety
Class III
Immunity to interference
EN 61000-6-2
Emitted interference
EN 61000-6-4
Table 15: Operating data
Minimum
Typical
Maximum
Ambient operating temperature
(UL/CSA: ambient temperature)
–25 °C
–
55 °C
Storage temperature
–25 °C
–
+70 °C
Air humidity
10% to 95%, non-condensing
Climatic conditions
EN 61131-2
Table 16: Mechanical strength
Minimum
Typical
Maximum
Vibration
EN 61131-2
Vibration resistance
5–500 Hz/5 grms (EN 60068-2-64)
Table 17: Terminal and connection data
Minimum
Typical
Maximum
Single-wire or fine-stranded
1 × 0.14 mm² to 2.5 mm² or
2 × 0.14 mm² to 0.75 mm²
Fine-stranded with ferrule in accor‐
dance with EN 46288 (1x)
1 × 0.25 mm² to 2.5 mm² or
2 × 0.25 mm² to 0.5 mm²
Stripping length
–
–
8 mm
Maximum tightening torque
–
–
0.6 Nm
For UL-508 and CSA applications
UE410-SD3xx
Connection cross-section
AWG 30–12 (use only 60/75 °C copper wire)
Tightening torque
5–7 lb
•
in
UE410-SD4xx
Connection cross-section
AWG 30–12 (use only 60/75 °C copper wire)
TECHNICAL DATA
13
8021417/2018-01-17 | SICK
O P E R A T I N G I N S T R U C T I O N S | UE410 Safeguard Detector Box
41