7
Configuration
7.1
Safety
DANGER
Hazard due to lack of effectiveness of the protective device
In the case of non-compliance, it is possible that the dangerous state of the machine
may not be stopped or not stopped in a timely manner.
Any change to the configuration can influence the effectiveness of the protective
device.
b
Check the effectiveness of the protective device after any change to the configura‐
tion.
7.2
Positioning and aligning the sensors
DANGER
The detection zone of the sensors (30 to 100 mm) cannot be changed. This is why cor‐
rect positioning of the sensor is crucial for safe functioning of the UE410 Safeguard
Detector Box safety system.
The safety system must switch off the system
before
the necessary number of objects
in the infeed for maintaining protection is undercut. Otherwise this would mean that the
user is at risk.
b
Apply/switch on voltage supply (U
V
= 24 V). The green status LED lights up on the
sensor.
b
Align the objects as they are to be detected in use.
b
Fill the magazine with objects until an interruption is effectively prevented.
b
Align the sensor at an angle to the front object,
see "Positioning the sensors in
relation to one another", page 17
.
b
The red emitted light beam must hit the object within the detection zone (30 to
100 mm). The yellow status LED must light up.
b
Move the sensor far enough away from the object that the maximum detecting of
100 is barely exceeded. The yellow Status LED may not light up.
b
Fix the sensor in the desired position. Observe the maximum permissible tighten‐
ing torque of the fixing screws of 0.8 Nm.
b
Repeat the procedure for the second scanner.
NOTE
•
Ensure that the optical opening (front screen) of the sensor is completely clear.
•
The sensors are set ex works and ready for operation. No further configuration
adjustments can be made.
7.3
Configuration of the UE410-SD
Operating modes
The UE410-SD can be operated with one or two sensor pairs.
The operating mode is adjusted using the wiring of input I1,
.
CONFIGURATION
7
8021417/2018-01-17 | SICK
O P E R A T I N G I N S T R U C T I O N S | UE410 Safeguard Detector Box
27
Subject to change without notice