7.4.3.3
Teaching in switching window (Window Mode)
Overview
When the object is located within the taught-in switching window, the digital output is
active.
Approach
2
1
1.
Position the object at
1
.
2.
Apply
M
at MF for 3 seconds until both
LED 3
and
LED 4
are flashing simultaneously.
✓
LED 3
and
LED 4
flash alternately.
3.
Position the object at
2
.
✓
LED 3
and
LED 4
flash alternately.
4.
Apply
M
at MF for 1 second.
✓
The switching points are taught in. The device automatically switches to normal
operation mode.
7.4.3.4
Teaching in background (Window Mode
±
8%)
Overview
When the object is located either below the taught-in reflector -10 mm (IO-Link: -8 %) or
above the taught-in ref10 mm (IO-Link: +8 %), the digital output is active.
Approach
1
– 10 mm
+ 10 mm
1.
Position the background at
1
.
2.
Apply
M
at MF for 3 seconds until both
LED 3
and
LED 4
are flashing simultaneously.
✓
LED 3
and
LED 4
flash alternately.
3.
Apply
M
at MF for 10 seconds until
LED 3
and
LED 4
stop flashing.
✓
The background is taught in. The device automatically switches to normal opera‐
tion mode.
7.4.3.5
Adjusting the N/C contact and N/O contact
Approach
1.
Apply
M
at MF for 13 seconds until both
LED 3
and
LED 4
flash alternately.
✓
LED 3
flashes orange.
✓
N/O contact:
LED 4
lights up green.
✓
N/C contact:
LED 4
does not light up.
2.
To change the setting, apply
M
at MF for 1 second.
3.
Wait 10 seconds.
✓
N/C and N/O are adjusted. The device automatically switches to normal operation
mode.
7
OPERATION
30
O P E R A T I N G I N S T R U C T I O N S | UC40
8027772//2022-08-11 | SICK
Subject to change without notice