7.3.2.3
Teaching in switching window (Window Mode)
Overview
When the object is located within the taught-in switching window, the digital output is
active.
Approach
2
1
1.
Position the object at
1
.
2.
Press
T2
pushbutton for 3 seconds until
LED 1
and
LED 2
flash simultaneously.
✓
LED 1
and
LED 2
flash alternately.
3.
Position the object at
2
.
✓
LED 1
and
LED 2
flash alternately.
4.
Press
T2
for 1 second.
✓
The switching points are taught in. The device automatically switches to normal
operation mode.
7.3.2.4
Teaching in background (Window Mode
±
8%)
Overview
When the object is located either below the taught-in reflector -10 mm (IO-Link: -8 %) or
above the taught-in ref10 mm (IO-Link: +8 %), the digital output is active.
Approach
1
– 10 mm
+ 10 mm
1.
Position the background at
1
.
2.
Press
T2
pushbutton for 3 seconds until
LED 1
and
LED 2
flash simultaneously.
✓
LED 1
and
LED 1
flash alternately.
3.
Press
T2
for 10 seconds until
LED 1
and
LED 2
stop flashing.
✓
The background is taught in. The device automatically switches to normal opera‐
tion mode.
7.3.2.5
Adjusting the N/C contact and N/O contact
Approach
1.
Press
T2
pushbutton for 13 seconds until
LED 1
and
LED 2
flash alternately.
✓
LED 1
flashes orange.
✓
N/O contact:
LED 2
lights up green.
✓
N/C contact:
LED 2
does not light up.
2.
To change the setting, press
T2
for 1 second.
3.
Wait 10 seconds.
✓
N/C and N/O are adjusted. The device automatically switches to normal operation
mode.
OPERATION
7
8027772//2022-08-11 | SICK
O P E R A T I N G I N S T R U C T I O N S | UC40
23