4
Technical data
Note
NOTE
This chapter contains an extract of the technical data. For full details, see the TMM55,
TMS/TMM88 (8019180) and TMS/TMM88 Dynamic (8023359) product information
4.1
Technical data for TMS88A- TMM88A-PKC090
Table 2: Technical data for TMx88A-PKCxxx
General parame‐
ters
1
TMS88A-PKC360
TMM88A-PKC090
Number of measur‐
ing axes
1
2
Measuring range
360°
±90°
Resolution
0.01°
0.01°
Accuracy
Range
0...360°
Typical
±0.04°
Maximum
±0.12°
Range
up to ±60°
up to ±70°
up to ±80°
up to ±85°
Typical
±0.02°
±0.04°
±0.08°
±0.16°
Maximum
±0.06°
±0.12°
±0.24°
±0.48°
Cross sensitivity
(compensated)
-
Typ. ±0.09° (±0.10%FS)
Max. ±0.45° (±0.50%FS)
Temperature coeffi‐
cient (zero point)
Typ. +0.0088 °/K, -0.0102 °/K
Sampling rate
100 Hz
Limit frequency
Typ. 20 Hz, 2nd order (no digital filter) / 0.1 ... 25 Hz, 8th order (with
digital filter)
Operating tempera‐
ture
-40 °C to +80 °C
Properties
Current interface
Freely configurable output in the range 0...20.48 mA (factory setting:
4...20 mA)
Freely configurable angle range 0...360° / ±90°
Functions
Teach input for zero-point setting when installed
Limitation of final value, counting direction, and axis assignment of out‐
puts can be configured
Digital filter (critically damped (default) or Butterworth low pass, 8th order)
Electrical parameters
Supply voltage
17 ... 35 VDC
Current consump‐
tion
40 mA @ 24 V + I
loop
Outputs (short-cir‐
cuit protected)
Inductive load less than 1 H, load dependent on input voltage (
)
Mechanical parameters
Connection
5-pin M12 sensor plug connector (male connector)
Enclosure rating
IP65/67
4
TECHNICAL DATA
8
O P E R A T I N G I N S T R U C T I O N S | TMS/TMM88, TMS/TMM55
8019053/1EF6/2021-12-13 | SICK
Subject to change without notice