l
Automatic: to assign the Node IDs to all sensors at once. To be performed when all
the sensors are connected.
l
Semi-automatic: wizard for connecting the sensors and assign the Node ID one
sensor at a time.
5.14.2
Procedure
1. Start the application.
2. Click
User
>
Configuration
and verify that the number of sensors in the
configuration is the same of the sensors installed.
3. Click
Settings
>
Node ID Assignment
.
4. Proceed according to the type of assignment:
If the assignment is...
Then...
manual
1. Click
DISCOVER CONNECTED SENSORS
to display the
connected sensors.
2. To assign a Node ID, click
Assign
for the unassigned Node
ID in the
Configured sensors
list.
3. To change a Node ID, click
Change
for the already assigned
Node ID in the
Configured sensors
list.
4. Select the SID of the sensor and confirm.
automatic
1. Click
DISCOVER CONNECTED SENSORS
to display the
connected sensors.
2. Click
ASSIGN NODE IDS
>
Automatic
.
semi-automatic
Click
ASSIGN NODE IDS
>
Semi-automatic
and follow the
instructions displayed.
5.15
Chain examples
X
Chain with control at the end of the chain and
a sensor with termination connector
Y
Chain with control inside of the chain and two
sensors with termination connector
5.16
Save and print the configuration
1. In the application, click
APPLY CHANGES
: the sensors will save the inclination set
and the surrounding environment. The application will transfer the configuration to
the control, and once transfer is complete it will generate a configuration report.
2. Click
to save and print the report.
Note
: to save the PDF, a printer must be installed on the computer.
3. Ask the authorized person for a signature.