8024924/1FGF/2022-03-01 | SICK
Subject to change without notice
M O U N T I N G I N S T R U C T I O N S | safeRS, safeRS3
34
MOUNTING INSTRUCTIONS
5.8
Install safeRS Sensor on the floor
Note
: for installation with Metal protector kit (product code 5341984), see the
instructions supplied with the kit.
1. Position the sensor as indicated in the configuration report and fasten the bracket
with two tamper-proof screws directly onto the floor or another support.
E
NOTICE
Indicates obligations that if not observed may cause harm to the equipment.
To tilt the sensor, loosen the side screws.
F
2. Direct the sensor up to the desired inclination.
Note
: a notch is equal to 10° of inclination.
G
NOTICE
Indicates obligations that if not observed may cause harm to the equipment.
3. Tighten the screws.
H
5.9
Install safeRS Sensor on the machinery
Note
: if the sensor is installed on parts that vibrate and objects are present in the field
of view, the sensor could generate undesired alarms.
1. Position the sensor as indicated in the configuration report and fasten the bracket
with two screws to a machinery support.
I
NOTICE
Indicates obligations that if not observed may cause harm to the equipment.
2. To tilt the sensor, loosen the side screws.
J
3. Position the sensor parallel to the machinery support.
Note
: a notch is equal to 10° of inclination.
K
NOTICE
Indicates obligations that if not observed may cause harm to the equipment.
4. Direct the sensor up to the desired inclination.
L
5. Tighten the screws.
M