3 Installation
3.1 Power Supply
The PGT-09-S can be alternatively powered by:
an external power-supply (12V DC) as the one that is part of the delivery.
the HIPERFACE DSL
®
connection
The power-supply connector (jack type) is placed on the panel opposite to the HIPERFACE
DSL
®
connectors.
Please check that the required polarity is matching with the following specification.
Supply voltage DC 12V
±
10%
-
+
The PGT-09-S can supply a connected HIPERFACE DSL
®
encoder (DSL OUT) with power. It is
not possible to supply a second PGT-09-S connected to the DSL IN or OUT ports.
Please note that the supply voltage of the PGT-09-S matches with the supply
voltage range of a connected HIPERFACE DSL
®
encoder (usually 7-12 VDC).
Supplying a PGT-09-S with a voltage higher than the rated encoder supply will
lead to irreversible damage to a connected encoder.
The two specific pins of the HIPERFACE DSL
®
connectors (M12, pin 4 and 3, PWR+ and PWR-
respectively) must be used to feed or draw power.
Connector
PIN
Signal
Description
DSL IN
1
2
4
3
1
DSL+
Data HIPERFACE
DSL
2
DSL-
Data HIPERFACE
DSL
3
PWR-
Ground connection
4
PWR+
12 VDC supply
voltage
DSL OUT
2
1
3
4
1
DSL+
Data HIPERFACE
DSL
2
DSL-
Data HIPERFACE
DSL
3
PWR-
Ground connection
4
PWR+
12 VDC supply
voltage
3.2 Ethernet connection
The PGT-09-S has an Ethernet port (RJ45) able to operate as 10BaseT or 100BaseTX mode,
Full-Duplex; the operating mode is automatically selected at start-up.
WARNING