4.
Screw the sensor in place accordingly.
Figure 8: Mounting on curved/uneven surface by means of adapter plate
Bonding with adhesive
In principle, a screw connection is always recommended. If this is not possible, an
epoxy-based adhesive can be used. An adapter plate should always be used to be
able to exchange the sensor.
1.
Prepare the adhesive according to its application description.
2.
Glue on the adapter plate.
3.
Allow the adhesive to cure.
4.
Screw the sensor in place accordingly.
Temporary mounting with magnets
Before using the accessories, make sure that the mounting surface is flat, not
curved and ferromagnetic.
CAUTION
Magnetic forces can cause the material to crush or shatter. Do not let your hands
get between the bracket and any ferromagnetic material. Wear gloves and protec‐
tive goggles when applying.
1.
Screw the sensor to the magnetic holder (part number: 2125439) on the side of
the magnetic holder shown in
according to the hole pattern.
Figure 9: Mounting side for mount‐
ing bracket