ELECTRICAL INSTALLATION
5
83
8017768/12AX/2019-05-31|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | TIC
5.4.1
Traffic Controller connection
5.4.1.1
Connecting the Traffic Controller to the voltage supply
The Traffic Controller should be connected to the voltage supply using the power cable
included with delivery. One end of the cable has a plug connector and the other is open.
The white and black wires must be connected to the voltage supply in the control cabinet.
The Traffic Controller and the 2D LiDAR sensors can be connected to the same voltage
supply.
▸
Plug the male connector of the power cable into the female connector on the Traffic
Controller and screw the connection tight.
▸
Connect the Traffic Controller to the voltage supply.
Fig. 90: Electrical installation of the TIC502 / TIC501 – Connecting the Traffic Controller to the
voltage supply
▸
Connect the wires of the black and white cable in the control cabinet as follows:
Wire color
Voltage supply
White
12 V … 36 V DC
Black
0 V
Tab. 15: Electrical installation of the TIC502 / TIC501 – Connecting the Traffic Controller to the
voltage supply
5.4.1.2
Connecting the Traffic Controller to the Ethernet switch
The Traffic Controller that has been mounted inside the control cabinet must be
connected to the Ethernet switch. The Ethernet switch connects the 2D LiDAR sensors to
the Traffic Controller.
▸
Connect the
Ethernet 2
connection of the Traffic Controller to the Ethernet switch.
Fig. 91: Electrical installation of the TIC502 / TIC501 – Connecting the Traffic Controller to the
Ethernet switch
Note