4
Device
5
Master
6
Device number
7
CAN etc.
8
Slave
9
Branch line
ß
Adapter cable (female connector, M12, 17-pin, A-coded/male connector, D-Sub-HD, 15-pin)
à
Device number (GN)
á
Maximum 32 users
â
Example of alternative connection module
CDB650-204
A connection cable 1:1 (female connector, M12, 17-pin, A-coded/male connector, M12, 17-pin, A-coded) is required to
connect the device
NOTE
Control the CAN data interface in the device with the API functions. In order to activate
the CAN data interface, use an installed SensorApp which contains this function.
13.4.7
Wiring digital inputs of the device in the CDM420-0006
Device
5
CDM420-0006
PNP sensor
9
V
S
V
S
V
S
GND
SensGND
3.32 K
6.64 K
Sensor
E
V
in
D
9
2
1
C
15
1
5
Out
+24V*
GND
S6
ON
OFF
S6 : SGND-GND
Shield
GND
.
.
.
A
Sensor
B
37 SGND
6 Shield
39 +24 V*
GND
SensGND
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
Trigger sensor
1
ß
E.g. photo-electric
switch
8
4
7
6
1
10
15
6
11
5
Cable
2
Cable
3
Figure 39: Trigger sensor supplied with power by connection module CDM420-0006
1
Trigger sensor
2
Connecting cable for 15-pin male connector (not available)
3
Adapter cable (male connector, D-Sub-HD, 15-pin / female connector, M12, 17-pin, A-coded)
4
Input voltage V
in
5
Device
6
Male connector, M12, 17-pin, A-coded
7
Connection module: female connector, D-Sub-HD, 15-pin
8
e.g. photoelectric sensor
9
PNP sensor
ß
Supply voltage V
S
ANNEX
13
8024439//2019-06 | SICK
O P E R A T I N G I N S T R U C T I O N S | InspectorP621
69