Electrical data
Risk time
4)
< 20 ms
1)
Within the limits of U
V
.
2)
AT 50 mA at each OSSD channel
3)
Once the supply voltage has been switched on, the OSSDs are in the OFF state during the time delay
before availability.
4)
The risk time is the time needed to detect internal and external faults. External errors affect the OSSDs
(short-circuit to an OSSD and cross-circuit between the two OSSDs). At least one of the two OSSDs is
safely switched off during the risk time.
Table 15: Mechanical data
Dimensions
see "Dimensional drawings", page 28
Material IME2S
Housing
Nickel plated brass
Sensor surface
Vistal
®
Cable
PVC
Fixing nuts
Brass alloy
Tightening torque for mounting
IME2S
12 Nm
Weight
see "Table of weights", page 28
Table 16: Outputs
Outputs
Switching outputs
2 PNP semiconductors
Switching voltage
ON state
19.2 V DC … 28.8 V DC
OFF state
0 V DC … 2 V DC
Switching current
ON state
≤ 50 mA
OFF state
< 500 µA
Load capacity
80 nF
Short-circuit protection
Yes
Reverse polarity protection
Yes
Test pulse width
300 µs
Table 17: Ambient data
Ambient data
Enclosure rating
IP 67 (IEC 60529)
1)
Ambient operating temperature
–25 °C … +70 °C
Temperature change rate
≤ 1 °K/min
Storage temperature
–25 °C … +70 °C
Area of application (IEC 60654-1)
Class C; weather-protected area of application
Operating altitude
≤ 3,000 m above sea level
Relative humidity
50% at 70 °C (IEC 60947-5-2)
Vibration resistance
1 mm / 10 Hz … 55 Hz (IEC 60947-5-2)
Shock resistance
In accordance with IEC 60947-5-2