Figure 8: No potential difference between load and protective device
6.2
Notes on cULus
Important information
DANGER
Risk of burns from hot housing
b
Take measures to make sure the safety switch cannot be touched during opera‐
tion.
For use according to the requirements of UL 60947-5-2, the following conditions must
also be met:
•
The voltage supply must correspond to Class 2 in accordance with UL 508
•
Voltage supply U
v
secured with 1 A fuse
6.3
System connection (M12, 4-pin)
1
2
3
4
Figure 9: System connection pin assignment (male connector)
Table 6: Device connection pin assignment (male connector, M12, 4-pin, A-coded)
Pin
Wire color
1)
Designation
Description
1
Brown
+24 V DC
Voltage supply 24 V DC
2
White
OSSD 1
Output OSSD1
3
Blue
0 V
Voltage supply 0 V DC
4
Black
OSSD 2
Output OSSD2
1)
Applies to the extension cables recommended as accessories.
b
Pay attention to seal tightness of the plug connector.
ELECTRICAL INSTALLATION
6
8023341/14TD/2019-08-08 | SICK
O P E R A T I N G I N S T R U C T I O N S | IME2S
19