11
Technical data
11.1
Data sheet
Table 10: Safety-related parameters
Safety-related parameters
Performance level
PL d (EN ISO 13849-1:2015)
Category
Category 2 (EN ISO 13849-1:2015)
Safety integrity level
SIL 2 (IEC 61508)
SIL claim limit
SILCL 2 (IEC 62061)
PFHd (mean probability of a dangerous failure per hour)
For operating heights ≤ 1,000 m above sea
level
6 × 10
–8
at 40 °C
For operating heights 1,001 m … 2,000 m
above sea level
7 × 10
–8
at 40 °C
For operating heights 2,001... 3,000 m
above sea level
8 × 10
–8
at 40 °C
T
M
(mission time)
20 years (EN ISO 13849–1:2015)
Type
Type 3 (ISO 14119)
Safe status when a fault occurs
At least one safety-related semiconductor out‐
put (OSSD) is in the OFF state.
Table 11: Features
Features
Assured switch-on distance S
ao
1)
IME2S**-04*****
3.2 mm
IME2S**-08*****
6.5 mm
IME2S**-05*****
4 mm
IME2S**-12*****
9.6 mm
IME2S**-15*****
12 mm
Assured switch off distance S
ar
1)
IME2S**-04*****
6 mm
IME2S**-08*****
12 mm
IME2S**-05*****
7.5 mm
IME2S**-12*****
18 mm
IME2S**-15*****
22.5 mm
Sensing range S
n
1)
IME2S**-04*****
4 mm
IME2S**-08*****
8 mm
IME2S**-05*****
5 mm
IME2S**-12*****
12 mm
IME2S**-15*****
15 mm
Actuating frequency
≤ 100 Hz
1)
Specified values apply to steel (FE360). A correction factor must be used for other materials
TECHNICAL DATA
11
8023341/14TD/2019-08-08 | SICK
O P E R A T I N G I N S T R U C T I O N S | IME2S
25
Subject to change without notice