Operating instructions
Chapter
4
ICR 84x Image Code Reader
Installation
8 010 961/0000/10-05-2005
©
SICK AG · Division Auto Ident · Germany · All rights reserved
4-1
4
Installation
4.1
Overview of installation sequence
•
Selecting the installation location for the ICR
•
Aligning the ICR with the code (adjusting the reading distance)
•
Mounting the ICR
•
Installing the CDB 420 or CDM 420 Connection Module
•
Connecting the IRC to the CDB 420 or CDM 420 Connection Module
•
Adjusting the ICR
•
Installing the reading pulse sensor for triggering the reading pulse
Note
Don’t open the device. The producer warranty will be forfeited if the device is opened.
4.2
Installation preparations
4.2.1
Laying out the components to be installed
•
ICR 84x Image Code Reader
4.2.2
Laying out accessories
•
Mounting bracket no. 2 025 491 with 2 M5 x 16 mm (0.63 in) screws (not included in
the ICR scope of delivery)
– or –
Alternatively, if the bracket is supplied by the user:
Stable installation device that allows the alignment of the ICR to be varied in the x and
y axes. The ICR weighs approx. 900 g (31.75 oz) with the connection cable.
Two M5 screws for the ICR. The screw length depends on the wall thickness of the
bracket used. Depth of engagement in
ICR max. 8 mm
(0.31 in)
from housing surface
•
CDB 420 or CDM 420 Connection Module (not included in the scope of delivery of the
ICR)
•
Reading pulse sensor(s) for external reading pulse trigger, e. g. photoelectric reflex
switch(es)/photoelectric proximity switch(es) (not included in the scope of delivery of
the ICR)
4.2.3
Laying out the required tools
•
Two M5 screws for fastening the SICK mounting bracket (strength: 8 mm (0.31 in)) to
the installation base. The screw length depends on the wall thickness of the base
•
Tool
•
Protractor