Table 10: % of sensing range
0
100
(3.94)
200
(7.87)
300
(11.81)
400
(15.75)
500
(19.67)
600
(23.62)
100
10
1
Operating reserve
Distance in mm (inch)
3
2
1
Figure 2: Redlight
0
1,000
100
10
1
Operating reserve
400
(15.75)
200
(7.87)
1,000
(39.37)
600
(23.62)
800
(31.50)
Distance in mm (inch)
3
2
1
Figure 3: Infraredlight
y
x
Figure 4: Description of the sensing range areas
7.3
Setting
Sensing range setting
Sensor which it is not possible to set: The sensor is adjusted and ready for operation.
Refer to graphic to check the function. If the switching output fails to behave in accor‐
dance with graphic, check application conditions. See section Fault diagnosis.
Sensor with potentiometer (without IO Link):
The sensing range is adjusted relative to the background with the potentiometer (type:
270°).
Clockwise rotation: sensing range increased; counterclockwise rotation: sensing range
reduced.
Turn the potentiometer clockwise until the yellow LED indicator lights up. When an
object is moved into the path of the beam, the yellow LED indicator must go out. If the
yellow LED indicator remains lit when an object is moved into the path of the beam,
repeat the adjustment.
COMMISSIONING
7
8017851.1A15 / 2020-12-14 | SICK
Subject to change without notice
17
Summary of Contents for HTE18 Series
Page 1: ...O P E R A T I N G I N S T R U C T I O N HTE18 Hybrid photoelectric sensors ...
Page 25: ...B E T R I E B S A N L E I T U N G HTE18 Hybrid Lichtschranken de en es fr it ja pt ru zh ...
Page 95: ...I N S T R U C C I O N E S D E U S O HTE18 Fotocélulas híbridas de en es fr it ja pt ru zh ...
Page 141: ...操 作 指 南 HTE18 混合光电传感器 de en es fr it ja pt ru zh ...
Page 164: ...取 扱 説 明 書 HTE18 ハイブリッド光電スイッチ de en es fr it ja pt ru zh ...