-xxxxxI
2
Q1 = L.ON
Adjustabl
e OFF
Delay
-xxxxxD
-xxxxxG
-xxxxxK
1
-xxxxxN
Q1 = D.ON
-xxxxxK
2
Q1 = L.ON
1
L/D Selection Switch in in the “D” Dark Switching position
2
L/D Selection Switch in in the “L” Light Switching position
7
Commissioning
7.1
Alignment
Sensor with infrared light (not visible):
Align sensor on object. Select the position so that the infrared light hits the center of
the object. The correct alignment can be detected via the signal strength light bar on
the back of the sensor and the LED on the top of the sensor. See
.
You must ensure that the optical opening (front screen) of the sensor is completely
clear.
Figure 1: Alignment
7.2
Check the application conditions
Sensing range
Check the application conditions: Adjust the sensing range and the remission capability
of the object according to the corresponding diagram [see
]. (x = sensing range,
y = operating reserve).
During this process, an object can only be detected in front of a background if the
remission capability of the object is significantly higher than that of the background or if
the distance between the object and the background is sufficiently long.
7
COMMISSIONING
16
8017851.1A15 / 2020-12-14 | SICK
Subject to change without notice
Summary of Contents for HTE18 Series
Page 1: ...O P E R A T I N G I N S T R U C T I O N HTE18 Hybrid photoelectric sensors ...
Page 25: ...B E T R I E B S A N L E I T U N G HTE18 Hybrid Lichtschranken de en es fr it ja pt ru zh ...
Page 95: ...I N S T R U C C I O N E S D E U S O HTE18 Fotocélulas híbridas de en es fr it ja pt ru zh ...
Page 141: ...操 作 指 南 HTE18 混合光电传感器 de en es fr it ja pt ru zh ...
Page 164: ...取 扱 説 明 書 HTE18 ハイブリッド光電スイッチ de en es fr it ja pt ru zh ...