8
Troubleshooting
The Troubleshooting table indicates measures to be taken if the sensor stops working.
Table 4: Troubleshooting
LED indicator/fault pattern
Cause
Measures
Yellow LED does not light up
even though the light beam is
aligned to the object and the
object is within the set sensing
range
No voltage or voltage below
the limit values
Check the power supply,
check all electrical connec‐
tions (cables and plug connec‐
tions)
Voltage interruptions
Ensure there is a stable power
supply without interruptions
Sensor is faulty
If the power supply is OK,
replace the sensor
Yellow LED flashes
Sensor is still ready for oper‐
ation, but the operating condi‐
tions are not ideal
Check the operating condi‐
tions: Fully align the beam
of light (light spot) with the
object / Clean the optical sur‐
faces / Check sensing range
and adjust if necessary
Yellow LED lights up, no object
in the path of the beam
Excessive background remis‐
sion
Check changes to the back‐
ground. Reduce the sensitivity
of the sensor or use sensors
with background suppression
Object is in the path of the
beam, yellow LED does not
light up
Sensitivity is set too low or dis‐
tance between the sensor and
the object is too long
Increase the sensing range,
take note of the distance
between the sensor and the
background
Object is in the path of the
beam, yellow LED does not
light up
Remission capability of the
object is insufficient
Increase the sensing range,
take note of the distance
between the sensor and the
background
9
Disassembly and disposal
The sensor must be disposed of according to the applicable country-specific regula‐
tions. Efforts should be made during the disposal process to recycle the constituent
materials (particularly precious metals).
NOTE
Disposal of batteries, electric and electronic devices
•
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
•
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
•
WEEE:
This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
TROUBLESHOOTING
8
8025471.1BHT / 2021-04-19 | SICK
Subject to change without notice
11
Summary of Contents for GTE6L Series
Page 1: ...O P E R A T I N G I N S T R U C T I O N GTE6L Miniature photoelectric sensors ...
Page 15: ...B E T R I E B S A N L E I T U N G GTE6L Miniatur Lichtschranke de en es fr it ja ko pt ru zh ...
Page 28: ...I N S T R U C C I O N E S D E U S O GTE6L Fotocélulas miniatura de en es fr it ja ko pt ru zh ...
Page 67: ...取 扱 説 明 書 GTE6L 超小型光電センサ de en es fr it ja ko pt ru zh ...
Page 80: ...작 동 지 침 서 GTE6L 소형 광전 센서 de en es fr it ja ko pt ru zh ...
Page 118: ...操 作 指 南 GTE6L 微型光电传感器 de en es fr it ja ko pt ru zh ...