NOTE
When mounting through beam photoelectric sensors adjacent to each other, alternate
the sender (GS6L) and receiver (GE6L) arrangement every other pair. Also ensure that
there is sufficient distance between pairs based on the sender (GS6L) light spot diame‐
ter. Refer to
Receiver (GE)
Receiver (GE)
Sender (GS)
Sender (GS)
Sender (GS)
Receiver (GE)
Figure 1: Arrangement of several through-beam photoelectric sensors
Sensor
Ø 70
(2.76)
Ø 3.5
(0.14)
Ø 90
(3.54)
Ø 120
(4.72)
Distance in m (feet)
Diameter in mm (inch)
1
(3.28)
12
(39.37)
30
(98.43)
40
(131.23)
Figure 2: GSE6L
6
Electrical installation
The sensors must be connected in a voltage-free state (U
V
= 0 V). The following informa‐
tion must be observed depending on the connection type:
–
Plug connection: pin assignment
–
Cable: wire color
Only apply voltage/switch on the voltage supply (U
V
> 0 V) once all electrical connec‐
tions have been established.
Explanation of connection terminology:
BN = Brown
WH = White
BU = Blue
BK = Black
n. c. = no connection
Q = switching output 1
Q
= switching output 2
L+ = supply voltage (Uv)
M = common
L.ON = light operate
ELECTRICAL INSTALLATION
6
8025390 | SICK
Subject to change without notice
7
Summary of Contents for GSE6L Series
Page 1: ...O P E R A T I N G I N S T R U C T I O N GSE6L Miniature photoelectric sensors ...
Page 15: ...B E T R I E B S A N L E I T U N G GSE6L Miniatur Lichtschranke de en es fr it ja pt ru zh ...
Page 67: ...I N S T R U C C I O N E S D E U S O GSE6L Fotocélulas miniatura de en es fr it ja pt ru zh ...
Page 80: ...操 作 指 南 GSE6L 微型光电传感器 de en es fr it ja pt ru zh ...
Page 93: ...取 扱 説 明 書 GSE6L 超小型光電センサ de en es fr it ja pt ru zh ...