max. 90 Nm
Note the sensor’s maximum permissible tightening torque of 90 Nm.
5
Electrical installation
The sensors must be connected in a voltage-free state (U
V
= 0 V). The following informa‐
tion must be observed, depending on the connection type:
–
Male connector connection: pin assignment
–
Cable: wire color
Only apply voltage/switch on the voltage supply (U
V
> 0 V) once all electrical connec‐
tions have been established. The green LED indicator lights up on the sensor.
Explanations of the connection diagram (Tables 2 and 3):
Q /
Q
= switching outputs
n. c. = not connected
DC: 10... 30 V DC,
see „Technical specifications“, page 12
Table 2: DC
GRTE18(S)V
x11xxx
x13xxx
x24xxx
x23xxx
1
+ (L+)
+ (L+)
+ (L+)
+ (L+)
2
Q
n. c.
Q
n. c.
3
- (M)
- (M)
- (M)
- (M)
4
Q
Q
Q
Q
1= brn
2 = wht
3 = blu
4 = blk
0.14 mm
2
AWG26
1 = brn
-
3 = blu
4 = blk
0.14 mm
2
AWG26
1
2
4
3
1
2
4
3
ELECTRICAL INSTALLATION
5
8021181 | SICK
Subject to change without notice
7
Summary of Contents for GRTE18SV
Page 13: ...B E T R I E B S A N L E I T U N G GRTE18 S V Rundlichtschranken de en es fr it ja pt ru zh...
Page 68: ...GRTE18 S V de en es fr it ja pt ru zh...
Page 77: ...69 SICK 69 8021181 SICK Subject to change without notice 77...
Page 79: ...GRTE18 S V de en es fr it ja pt ru zh...
Page 88: ...LED LED LED 78 79 SICK 78 88 8021181 SICK Subject to change without notice...
Page 90: ...GRTE18 S V de en es fr it ja pt ru zh...
Page 99: ...87 87 1 45 C 88 89 SICK 87 8021181 SICK Subject to change without notice 99...