Use and Table 3 to check the function. If the switching output fails to behave in accordance
with Table 3, check the application conditions. See section Fault diagnosis.
3
Sensing range setting
Sensor which it is not possible to set: The sensor is adjusted and ready for operation.
The sensitivity (sensing range) is adjusted with the potentiometer (type: 270°). Clockwise
rotation: sensitivity (sensing range) increased; counterclockwise rotation: sensitivity (sens‐
ing range) reduced. We recommend placing the object within the sensing range. Once the
sensitivity is set, remove the object from the beam path. The switching output changes.
Table 4: Sensing range setting
The sensor is adjusted and ready for operation.
7
Troubleshooting
The Troubleshooting table indicates which measures are to be taken if the sensor stops
working.
7.1
Troubleshooting table
Table 5: Troubleshooting
LED indicator/fault pattern
Cause
Measures
Green LED does not light up
No voltage or voltage below
the limit values
Check the power supply,
check all electrical connec‐
tions (cables and plug connec‐
tions)
Green LED does not light up
Voltage interruptions
Ensure there is a stable power
supply without interruptions
Green LED does not light up
Sensor is faulty
If the power supply is OK,
replace the sensor
Yellow LED flashes
Sensor is still ready for opera‐
tion, but the operating condi‐
tions are not ideal
Check the operating condi‐
tions: Fully align the beam of
light (light spot) with the
object / Clean the optical sur‐
faces / Readjust the sensitiv‐
ity (potentiometer)
7
TROUBLESHOOTING
10
8021181 | SICK
Subject to change without notice
Summary of Contents for GRTE18SV
Page 13: ...B E T R I E B S A N L E I T U N G GRTE18 S V Rundlichtschranken de en es fr it ja pt ru zh...
Page 68: ...GRTE18 S V de en es fr it ja pt ru zh...
Page 77: ...69 SICK 69 8021181 SICK Subject to change without notice 77...
Page 79: ...GRTE18 S V de en es fr it ja pt ru zh...
Page 88: ...LED LED LED 78 79 SICK 78 88 8021181 SICK Subject to change without notice...
Page 90: ...GRTE18 S V de en es fr it ja pt ru zh...
Page 99: ...87 87 1 45 C 88 89 SICK 87 8021181 SICK Subject to change without notice 99...
Page 100: ...100 8021181 SICK Subject to change without notice...