EN
Operating
instructions
FFU
8 Technical data
46
8013863/10L9 /2018-08-01 © SICK AG • Fluid sensors • Germany • Subject to change without notice
8 Technical data
Features
NW10
NW15
NW20
NW25
Measuring principle
Ultrasonic sensor
Medium
Fluids
Nominal width measuring
tube
NW10
NW15
NW20
NW25
Process temperature
0 °C ... +80 °C
Process pressure
Max. 16 bar
Max. 10 bar
EHEDG approval
l
Performance
NW10
NW15
NW20
NW25
Minimum flow
1)
0.3 l/min
0.9 l/min
3.5 l/min
5 l/min
Maximum flow
21 l/min
36 l/min
60 l/min
240 l/min
Inlet zone
10 cm
30 cm
40 cm
40 cm
Outlet zone
0 cm
5 cm
10 cm
20 cm
Conductivity
No limitation
Accuracy
2)
2% (of final value)
optional 1% of r/- 3 mm/s
Reproducibility
0.5 %
Resolution
0.003 l/min
0.006 l/min
0.012 l/min
0.03 l/min
1)
At constant flow rate.
2)
reference condition:Medium: water, gas-free, fully-filled measuring tube, no cavitation, Medium temperature 20 ° C
Ambient temperature 20 ° C ... 25 ° C, Compliance with the inlet zone and outlet zone, Warm-up time electronic: 30 min
Mechanics
NW10
NW15
NW20
NW25
Process connection
G 1/2
1/2“ NPT
Clamp 11864
G 3/4
3/4“ NPT
Clamp 11864
G 1
1“ NPT
Clamp 11864
G 1 1/4
1 1/4“ NPT
Clamp 11864
Wetted parts
PSU
Housing material
PSU
Enclosure rating
IP 67
Weight
340 g
350 g
420 g
460 g