124
8020216/19YN/V3-0/2020-12| SICK
O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER SP100 Ex-3K
Subject to change without notice
15
TECHNICAL DATA
15
Technical data
DUSTHUNTER SP100 Ex-3K system (Zone 2/22)
Table 31: Technical data, complete system
Measured variable
Scattered light intensity
(dust concentration output in mg/m³ after gravimetric comparison measurement)
Measuring principle
Scattered light measurement (forward dispersion)
Spectral range
640 nm … 660 nm
Laser, protection class 2, capacity <1 mW
Measuring range (freely
adjustable)
Dust concentration
0 ... 5 mg / m³ /0 ... 500 mg/m³
Higher measuring ranges on request
Certified measuring ranges
Dust concentration
0…7.5 mg/m³
(additional measuring ranges 0…10, 0…15, 0…50, 0…100, 0…200, 0…500 mg/m³)
Response time (t90)
1 … 600 seconds
Freely adjustable
Precision
≤
2%
of measuring range end value
Process temperature
Standard version
DHSP-T2xxxxEx3K
High temperature version
DHSP-T4xxxxEx3K
-15 °C ... +220 °C
-15 °C ... +400 °C
Process pressure
With instrument air
(from customer)
-100 hPa ... +100 hPa (rel)
Process gas moisture
Non-condensing
Internal duct diameter
≥
0.25 m
Compliances
Approved for systems requiring approval:
2001/80 /EC (13. BlmSchV)
2000/76/EC (17. BlmSchV)
27. BlmSchV
TI-Air
EN 15267
EN 14181
2010/75/EU
2014/34/EU
2014/30/EU
U.S. EPA PS-11 compliant
Electrical safety
CE
Control functions
Automatic self-test (linearity, contamination, drift, aging)
Contamination limits: At 30% warning, at 40% malfunction
Manual linearity test via reference filter