PRODUCT DESCRIPTION
3
3.4
Explosion protection in accordance with ATEX
3.4.1
Operation in the Ex-zone
DUSTHUNTER SP100 Ex-3K sender/receiver unit
The marking of the electrical explosion-proof device is:
ATEX II 3G Ex nR op is IIC T6 Gc / ATEX II 3D Ex tc op is IIIC T85°C Dc
●
The marking is on the type plate
●
Type Examination Certificate: BVS 16 ATEX E 068 X
Letter “X” after the certificate number indicates the following special
condition for safe use of the device:
The maximum surface temperature of the electronic housing is 70 °C. The
external heat source (duct walls) must be insulated so that 70 °C is not
exceeded.
MCUDH Ex-3K control unit
The marking of the electrical explosion-proof device depends on the device
selection (
see “Technical data”, page 124
●
The marking is on the type plate
●
Type Examination Certificate: BVS 20 ATEX E 043 X
Letter “X” after the certificate number indicates the following special
condition for safe use of the device:
●
Device is designed for degree of contamination 2.
●
It must
be ensured that the transient protection is set to a value not
exceeding 140% of the measured peak voltage on the supply terminals of
the device.
NOTE:
Hazard during operation in the Ex-zone
Risk of explosion when regulations on explosion protection are not observed during
operation.
▸
Only use the measuring system in the Ex-zone according to the device marking (
).
▸
Only use the measuring system within the temperature limits as specified in these
Operating Instructions as well as on the type plate.
The specified values must not be exceeded even for brief periods.
▸
The use of the measuring system with hybrid mixtures (mixture of combustible gases
or vapors with dust) must be evaluated according to the situation being considered,
e.g. regarding concentration limits or energy and temperature limits.
▸
Do not install any components, apart from the electronics unit of the sender/receiver
unit, in lines, tanks, or other installation areas where explosive gas and/or dust
mixtures may be present.
▸
The measuring system must not be operated with dust deposits thicker than 5 mm
on the electronics housing.
▸
Dust deposits must be removed regularly and properly.