8014753/ZVZ7/2018-03-22 • © SICK AG • Subject to change without notice 83
Operating instructions Distance measuring device DL100 Pro – RS-422
Technical data
14.4 Performance
Measurement ranges
• DL100–21XXXXXX: 0.15 m … 100 m
• DL100–22XXXXXX: 0.15 m … 200 m
• DL100–23XXXXXX: 0.15 m … 300 m
Measuring accuracy
•
Measuring range 0.15 m … 100 m: ± 2.0 mm
•
Measuring range 0.15 m … 200 m: ± 2.5 mm
•
Measuring range 0.15 m … 300 m: ± 3.0 mm
Repeatability
• Measuring range 0.15 m … 100 m: 0.50 mm
• Measuring range 0.15 m … 200 m: 1.00 mm
• Measuring range 0.15 m … 300 m: 2.00 mm
Initialization time
• Typical 1.5 s
•
After reflector loss: < 40 ms
Reaction time/dead time
2 ms
Resolution
Adjustable: 0.1 mm / 0.125 mm / 1.0 mm / 10 mm / 100 mm
Output rate
Synchronous to PLC request
Table 54: Performance data
14.5 Supply
Supply voltage V
S
18 V DC ... 30 V DC
Power intake
• Without heating: < 250 mA at 24 V DC
• With heating: < 1,000 mA at 24 V DC
Residual ripple
< 5 V
ss
within the permissible supply voltage V
S
Table 55: Supply
14.6 Inputs
Inputs
Multifunction input MF1, adjustable
• Hi > 12 V
• Lo < 3 V
→
Also see page 46, Table 13 parameter "ActStat".
Protective circuit
No, not reverse polarity protected
Table 56: Inputs