Operating Instructions
Chapter
11
CLV640 Bar Code Scanner
Appendix
8011975/0000/2008-04-14
©
SICK AG · Division Auto Ident · Germany · All rights reserved
113
11.4.4
Accessories: Extensions for connection modules
Order no.
Type
Description
Display
1042259
CMC600-
101
Parameter memory module (connection module cloning)
•
Plug-in using connection module
CDB620
or
CDM420
•
Storage of the parameter set of CLV640 (from firmware V 1.00)
•
Rotary switch for activating CLV640 network operation
•
Operating voltage 10 ... 30 V DC using CDB620 or CDM420
•
Current consumption 0.5 W
•
Operating temperature 0 ... +40 °C
2029466
CDM400
1)
Display module (connection display module)
•
In the optional housing cover for connection module
CDM420
•
Display of reading results and reading diagnosis data of CLV640
(from firmware V 1.00)
•
LCC with 4 x 20 characters, keyboard with 5 keys
•
Connection via flat cable
•
Operating voltage 18 ... 30 VDC using CDM420, current consump-
tion 1 W
•
Operating temperature 0 ... +40 °C
Prerequisite: Parameter memory module CMC600-101 for addressing
the display.
2029468
CMP400
Power supply module (connection module power)
•
Installed in connection module
CDM420
•
Power supply of CLV640 from the alternating current network
•
Input voltage 100 ... 250 VAC/50 ...60 Hz
•
Output voltage 24 V DC, max. 10.8 W (short-circuit proof)
•
Connection to CDM420 via flat cable
•
Operating temperature 0 ... +40 °C
2030091
CMP490
2)
Power supply module (connection module power)
•
In the optional housing cover for connection module
CDM420
•
Power supply of CLV640 from the alternating current network
•
Input voltage 100 ... 250 V AC/50 ...60 Hz
•
Output voltage 24 V DC, max. 25 W (short-circuit proof)
•
Connection to CDM420 via flat cable
•
Operating temperature 0 ... +40 °C
1026241
CMF400-
1001
Field bus gateway (connection module field bus)
•
Installed in connection module
CDM420
•
Connection of a CLV640 (from firmware V 1.00) via RS-232 data in-
terface to
Profibus DP
(slave)
•
Changeable front panel: 9-pole D-Sub socket (bus), enclosure rating
IP 20
•
On the gateway in the device, 5-pole terminal strip for connecting
two digital inputs and outputs each
•
Connection to CDM420 via connector
•
Operating voltage
18
... 30 VDC using CDM420, current consump-
tion 2 W
•
Operating temperature 0 ... +40 °C
•
Configuration with PC software "ComPro" (included in delivery)
•
Configuration with SOPAS-ET from Q4/2007