CLV620
Window material of the view‐
ing window
Plastic
Mounting elements
2 tapped blind holes M5
Alternative: 4 fixing holes, Ø
5.5
mm
Laserwarnschild
Lasered on
Safety
EN 62368-1: 2014-08
Enclosure rating
IP69K (DIN 40050, Part 9)
Test conditions:
•
Water spray volume: 14
l/min ... 16
l/min
•
Water pressure/temperature: 10000
KPa (100
bar) / 80
°C
•
Flat jet nozzle distance: 100
mm ... 150
mm
•
Spray angle: 0°, 30°, 60°, 90°
•
Cycle: 30
seconds per position
•
Rotational speed of test specimen: 5
rpm
Protection class
(Class 3, EN 61140)
For operation in SELV systems (EN 60950-1) or ES1 systems (EN 62368-1)
Weight
2)
854
g, with double protective bushing
Dimensions (L x W x H)
1)
85
mm x 84
mm x 154
mm
Conformity
CE.
For further conformities and certificates, see the product page on the Internet at:
1)
With digital outputs loaded.
2)
Without connecting cables.
3)
See also
Ambient data
CLV620
EMC test
Radiated emission: According to EN
61000-6-3: 2007-01
Shock resistance: According to EN
61000-6-2: 2005-08
Vibration resistance
EN 60068-2-6: 2008-02
Shock resistance
EN 60068-2-27: 2009-05
Ambient operating tempera‐
ture
0°
C ... +40
°C
Storage temperature
–20°
C ... +70
°C
Permissible relative humidity
0% ... 90%, non-condensing
Ambient light immunity
2,000 lx, on bar code
Bar code print contrast (PCS)
≥
60
%
7.2
CLV63x bar code scanner in the IP69K protective housing
NOTE
The relevant online data sheet for your product including technical data and dimen‐
sions can be downloaded from the Internet:
Features
CLV630
CLV631
CLV632
Working range
Long range
Mid range
Short range
TECHNICAL DATA
7
8021479/19ZB/2021-10-29 | SICK
T E C H N I C A L I N F O R M A T I O N | CLV62x, CLV63x and CLV64x with IP69K Protective Housing
33