Operating Instructions
Chapter
9
CLV 490 Bar Code Scanner
8 009 993/O824/20-12-2004
©
SICK AG · Division Auto Ident · Germany · All rights reserved
9-3
Technical data
9.4
Data sheet CLV 490-1011/-3011/-7011 bar code scanner
Technical data as CLV 490-1010/-2010/-6010 with the following exceptions:
9.5
Dimensioned drawings – CLV
9.5.1
Line scanner (standard device) without /with heater
Type
CLV 490-1011
(Standard density)
CLV 490-3011
(High density)
CLV 490-7011
(Low density)
Design
line scanner with oscillating mirror and heater
Switching on function/temperature graph
Chapter 10.4 Optional heating, Page 10-40
Power-on delay
35 to 40 min (at 24 V DC and min. ambient operating temperature –35
°
C (–31
°
F))
Operating voltage
24 V DC +20 %/–10 % pursuant to IEC 364-4-41
Power consumption
typically 75 W, max 90 W
Required cross-section
min. 0.75 mm
2
(20 AWG) (for power supply)
Weight
approx. 2.2 kg (approx. 4.84 lb)
Ambient operating/storage temperature
–35 to +35
°
C/–20 to +70
°
C (–31 to +95
°
F/–4 to +158
°
F)
Table 9-4: Technical specifications of the CLV 490-1011/-3011/-7011
Fig. 9-1:
Dimensions of the CLV 490 line scanner, front reading window
CLV 490-0010
CLV 490-0011
CLV 490-2010
CLV 490-2011
CLV 490-6010
CLV 490-6011
All dimensions in mm (in)