Chapter
6
Operating Instructions
CLV 490 Bar Code Scanner
6-26
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 993/O824/20-12-2004
Operation
Parameterize reading trigger:
Object polling
Ö
D
EVICE
CONFIGURATION
tab
Activating object polling:
Start:
Ö
R
EADING
T
RIGGER
S
OURCE
section
– Object polling
Stop:
Ö
R
EADING
T
RIGGER
S
OURCE
section
Ö
E
ND
OF
R
EADING
I
NTERVAL
section
– generated by Trigger Source
or
– Timer: Timeout (referred to beginning of reading interval)
or
– generated by IN 4
Ö
Using IN 4: D
EVICE
CONFIGURATION
tab
Ö
A
SSIGNMENT
OF
I
NPUTS
section
Ö
IN 4
– Reading Trigger Stop (Active High)
or
– Reading Trigger Stop (Active Low)
Configuring object polling:
Ö
O
BJECT
POLLING
P
ARAMETERS
button
Ö
P
OLLING
P
ROPERTIES
section
– Search time
– Pause time
– Minimum object recognition
– Minimum object width
Ö
O
BJECT
DETECT
SPACE
section
– Right edge of conveyor (Y 1)
– Left edge of conveyor (Y 2)
– Level of conveyor (Z 1)
– Maximum scanning height (Z 2)
Ö
S
CAN
ANGLE
LIMITATION
section
– Min. and max. angle
Oscillating mirror:
Ö
additionally: O
SCILLATING
ANGLE
LIMITATION
section
– Min. and max. value
Define scanner position referred to the conveyor belt:
Ö
see
, reading space, scanner position
Online diagnosis of configured object detection space:
Ö
Menu CLV 490
Ö
Background analysis
– Analysis: object detection
Output of reading result referred to beginning of reading
interval:
Ö
D
EVICE
CONFIGURATION
tab
Ö
O
UTPUT
ON
G
OOD
R
EAD
section
– End of reading gate
or
– Immediate
or
– End of Label
Ö
Using End of label: R
EADING
T
RIGGER
P
ARAMETERS
button
Ö
E
ND
OF
L
ABEL
/F
REE
-
RUNNING
section
– Timeout
Note:
No laser timeout function (defined switching off of laser diode
due to too long active reading gate) available in this trigger mode.
Action
Settings in CLV-Setup
Table 6-11: Guide: Parameterizing the reading trigger for start/stopp mode in stand-alone
configuration (contd.)