OPERATION
7
57
8027513/V1-0/2022-03|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | MDA Vision
7.2.3
Measurement value determination and data output
▸
After successful code reading, place the object in the
center
of the scale.
NOTE
The object must lie with its center of gravity on the scale.
Object overhang is tolerated if the object is completely within the field of view of the
Visionary-S 3D camera and the object is dimensionally stable.
▸
Release the object and remove your hands from the measuring field.
Fig. 52: Automatic determination of measured values
•
As soon as the object is free on the scale, weight and dimension values are determined
and displayed.
A successful determination of weight and measurement is visualized as follows:
•
The measuring station display is outlined in green after the measured value has been
successfully determined.
•
The measured object is displayed in green.
Everything that is not assigned to the measuring object is colored red in the measuring
station display (e.g., arms and hands).
•
Measurement and read data are output immediately if a network connection is
established.
If the object was placed on the scale without successful code reading:
▸
Move object on the scale until the code can be determined by the code reader or
record code with the mobile hand-held scanner (if connected).
▸
Release object.
•
Weight and dimensional values are determined later.
Display
Readjusting object