LED (red)
LED (green)
Phase
-
O
Monitoring mode:
Automated return after teach-in com‐
plete
All fields free
O
O
Monitoring mode:
If an object detection has occurred
O
= illuminated;
Ö
= flashing
The taught-in field contour is automatically and permanently saved as a new field set 1.
7.2.1.2
Field set selection via input wiring
One of the predefined field sets can be activated by wiring the digital inputs.
To select field sets via digital inputs, the
Digital inputs
field set selection method must be
set in the device. This is the case by default.
Field set factory settings – digital inputs
Field
set
Digital inputs
Field shape
Default size of field 1
IN 1
IN 2
IN 3
IN 4
1
0
0
0
0
Rectangle, segmented L: 1 m, W: 2 m
2
1
0
0
0
Rectangle, segmented L: 1.25 m, W: 2 m
3
0
1
0
0
Rectangle, segmented L: 1.5 m, W: 2 m
4
1
1
0
0
Rectangle, segmented L: 1.75 m, W: 2 m
5
0
0
1
0
Rectangle, segmented L: 1 m, W: 2 m
6
1
0
1
0
Rectangle, segmented L: 1.25 m, W: 2 m
7
0
1
1
0
Rectangle, segmented L: 1.5 m, W: 2 m
8
1
1
1
0
Rectangle, segmented L: 1.75 m, W: 2 m
9
0
0
0
1
Rectangle, segmented L: 1 m, W: 2 m
10
1
0
0
1
Rectangle, segmented L: 1.25 m, W: 2 m
11
0
1
0
1
Rectangle, segmented L: 1.5 m, W: 2 m
12
1
1
0
1
Rectangle, segmented L: 1.75 m, W: 2 m
13
0
0
1
1
Rectangle, segmented L: 1 m, W: 2 m
14
1
0
1
1
Rectangle, segmented L: 1.25 m, W: 2 m
15
0
1
1
1
Rectangle, segmented L: 1.5 m, W: 2 m
16
1
1
1
1
Rectangle, segmented L: 1.75 m, W: 2 m
Output form (rectangle), can be changed as desired, L = length, W = width
Input level: Low (in resting position): ≤ 2 V, high (in working position): ≥ 8 V
7.2.1.3
Field set selection via telegram
One of the predefined field sets can be activated by means of a telegram sent via the
Ethernet interface on the device. To select field sets via telegram, the “SOPAS telegram”
field set selection method must be set in the device. This can be done using a telegram
or via settings in SOPAS ET. The device can then be instructed via a telegram of the
predefined field set that is to be activated. Field set 1 is preselected by default.
Overview of the telegram functionality for field set selection:
•
Select the field set selection method (
sWN FieldSetSelectionMethod [0;1]
)
•
Read the field set selection method (
sRN FieldSetSelectionMethod
)
7
OPERATION
40
O P E R A T I N G I N S T R U C T I O N S | TiM781
8024231/1G72/2022-05-27 | SICK
Subject to change without notice