The USB connection (USB 2.0 Mini-B, female connector) may only be used temporarily
and only for configuration and diagnostics.
4
Mounting the safety laser scanner directly
Direct mounting:
The safety laser scanner has 4 M5 threaded holes on the back. If you are able to drill
through the mounting surface from the rear, you can mount the safety laser scanner
directly using these threaded holes.
b
Use either the rear
1
or the side
2
M5 threaded holes for direct mounting.
b
Use all four rear or all four side M5 threaded holes for direct mounting, so that the
values given in the data sheet for vibration and shock resistance are achieved.
b
Maximum depth of thread engagement: 7.5 mm.
b
Tightening torque: 4.5 Nm to 5.0 Nm.
5
Connection overview
MICSX-UBIZZZZZ1 (part number: 2101638)
6
Pin assignment
6.1
Connecting cable with M12 plug connector
Male connector, M12, 8-pin, A-coded.
7
6
8
5
4
2
3
1
Pin
Designation
Function
1
+24 V DC
Supply voltage (+24 V DC)
2
OSSD 1.A
OSSD pair 1, OSSD A
3
0 V DC
Supply voltage (0 V DC)
4
OSSD 1.B
OSSD pair 1, OSSD B
5
Uni-I/O 1
Universal I/O 1
6
Uni-I/O 2
Universal-I/O 2
7
Uni-I/O 3
Universal-I/O 3
8
FE
Functional earth/shield
7
Replacing the safety laser scanner
If the safety laser scanner is damaged or defective, you must replace it.
MOUNTING INSTRUCTIONS
10
M O U N T I N G I N S T R U C T I O N S | outdoorScan3 Core I/O
8023258/1G5N/2022-05-31 | SICK
Subject to change without notice
en