17
TEST button
18
R e l a i s N . O . 6 A t e r m i n a l b l o c k s
(removable)
20
Reflector lightbar
21
Wall mounting openable holes
22
Antiremoval magnet slot
23
Openable hole for cables
24
Magnet with plastic mounting clip
Installation
-
De le ting the re a der con fi gu ra tion pro ce e ding as
fol lows:
-
Re mo ve the back co ver pul ling gently on the bot -
tom [10];
-
Pla ce the bat tery into the re a der;
-
Press the TEST and RESET but ton;
-
Re le a se the RESET but ton ke e ping the TEST
but ton pres sed for se ve ral se conds; the four but -
ton on the front pa nel will be ilght in red and af ter
in gre en; now the con fi gu ra tion is re set.
19