Offset of slave ID
——
D-value of virtual ID with actual ID (can be negative);
Actual salve ID range
——
By clicking “Set” button to calculate;
When select “RTU slave mode”, the users need to specify the serial port to be mapped.
When select “RTU master mode”, the users need to set “IP address of target TCP slave”, that is the IP address
of the server to be connected.
After setting “Virtual slave ID range” and “Offset of slave ID”, click “Set” button, “Actual salve ID range”
value is automatically calculated.
When click “Add” button, users can add a message in “Slave ID mapping list”.
When want to modify the added information, users fist select the information you want to modify, and then
set “Virtual slave ID range” and “Offset of slave ID”, click “Modify” button.
When want to delete the added information, users need select the information you want to delete, and click
“Delete” button.
Tip: 1. “Add” and “Modify” button both have “Set” function, users do not need to click “Set” then click
“Add” or “Modify”.
2. Support up to 36 messages.
4.3.5 Modbus parameters
Set “Character time out”, “Response time out” and “Delay between polls” of Modbus RTU in the follow
interface: