Thank you for buying the QCA-W5 Quick Charger. Before using the 
QCA-W5, be sure to thoroughly read this manual to ensure correct use.   
Also, keep this manual in a safe place so that it can be referred to 
whenever necessary.   

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

19.06.19K (01) 

Safety Precautions

 

The precautionary information that appears in this manual is for 
ensuring that the product is used safely and for preventing injury to you 
and other people and damage to equipment. 
It is all important for ensuring safety and so be sure to read it thoroughly 
before using the product and observe it during use. 

Warning Indications 

DANGER:

  Impending danger is expected that 

might result in death or serious injury.   

WARNING:

  There is an expected risk that might 

result in death or serious injury.   

CAUTION:

  There is an expected risk of moderate 

injury or property damage.   

DANGER 

Misuse might cause electric shock, generation of heat, 
fire, or rupturing, which will result in burns, serious 
injury or blindness.   

•  Never use the QCA-W5 for charging devices other than the NI-W5 

Nickel metal-hydride battery. Also, never use the QCA-W5 for 
devices other than the MP-W5P.   

•  Never connect an AC adapter other than the exclusive 

RC60G-12D AC adapter (provided) to the QCA-W5.   

•  Do not disassemble or modify the QCA-W5 and RC60G-12D.   

•  Do not insert metal objects inside the product body.   

•  Do not leave the product near infants.   

•  Do not immerse the product in water or allow it to get wet.   

•  If you notice heat generation or abnormal odors, immediately 

disconnect the plug from the AC power outlet.   

•  Do not place heavy objects on the QCA-W5 or RC60G-12D, or 

subject them to dropping or other impact.   

 

WARNING 

Misuse might cause electric shock, generation of heat, 
fire, or rupturing, which will result in burns, injury or 
blindness.  

•  When connecting or disconnecting the MP-W5P, be sure to do so 

by holding the connector.   

•  Do not connect to an electronic type transformer.   

•  Do not charge a short-circuited NI-W5.   

•  Do not use the QCA-W5 near objects that generate heat or block 

heat discharge.   

•  Insert each of the connectors firmly as far as possible.   

 

CAUTION 

Misuse might cause moderate injury

 or physical damage. 

•  Connect connectors correctly.   

•  Charge indoors within a temperature range of 5 to 35°C.   

•  Do not charge or store in humid or dusty locations.   

•  When not charging, be sure to disconnect the RC60G-12D from 

the AC power outlet.   

Features

 

z

 Can charge NI-W5 nickel metal-hydride battery connected to the 

MP-W5P Mini Pump. 

z

 Can also be used as an AC adapter for the MP-W5P Mini Pump. 

z

 Can supply power for the MP-W5P while simultaneously charging the 

NI-W5.  

z

 Built-in micro-computer to enhance anti-overcharging and 

anti-overheating functions.   

z

 Simple battery voltage check.   

z

 The battery temperature is detected to charge at the appropriate 

temperature (5 to 35°C).   

z

 Compliant with RoHS directives. 

 
 

Connection Drawings 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 

 

Handling Method

 

(1) 

When connected as shown in the figure on the left, charging is 
started and the red LED flashes.   
When charging is completed, the red LED stops flashing and the 
green LED lights up. 

When the NI-W5 is installed in the MP-W5P and then   
the QCA-W5 is connected, AC drive is enabled while charging the 
NI-W5. 

When the QCA-W5 is connected to the MP-W5P without the NI-W5 
installed, AC drive is enabled. 

When a dry cell is installed in the MP-W5P and then the QCA-W5 is 
connected, AC drive is enabled.   
In this case, AC drive is enabled even when a dry cell type 
secondary battery is installed. However, the secondary battery is not 
charged.  

*  The RC60G-12D AC adapter for the QCA-W5 cannot be directly 

connected to the MP-W5P. Be sure to connect it as shown in the 
figure above. 

*  Although the RC60G-12D supports power supplies in countries other 

than Japan, its attached power plug is only for use in Japan. When 
using the RC60G-12D in a country other than Japan, provide a power 
plug suitable for the country's specifications. 

 

 

(2) 

If the red LED is lit even with the QCA-W5 connected, charging is 
not possible since the battery temperature at the start of charging is 
out-of-range. In this case, charging will start automatically as soon 
as the battery temperature returns to within the battery temperature 
range. The appropriate charging temperature range is 5 to 35 

°

C.  

*  Charging will stop midway if the battery temperature falls out of the 

temperature range 0 to 60°C. In this case, too, the red LED will light, 
and charging will start automatically as soon as the battery 
temperature returns to within the battery temperature range. 

(3)

  When both red and green LEDs are flashing, an error has occurred. 

If the cause of the error is unknown, contact your Sibata agent. 

 

(4)

 

The simple battery voltage check can be performed by pressing the 
button on the left of the LEDs. 
When both red and green LEDs light after pressing the button, the 
voltage is 8.6 V or more, and you can judge that the battery is about 
80% charged. 
When the red LED is lit and the green LED is flashing,   
the voltage is less than 8.6 V, which means that the battery must be 
charged. 

*  In a fully charged state (with the green LED lit), this function cannot 

be used. 

 
 

 

LED Display

 

 
 

 

Specifications

 

Item code 

080860-5054 

Model QCA-W5 

Input voltage range 

12 VDC (RC60G-12D must be used) 

Output voltage range 

9.0 VDC (2.0 A), 12 VDC (1 A) 

Operating temperature range 

5 to 35°C 

External dimensions 

85 (W) 

×

 120 (D) 

×

 29 (H) mm 

Weight 

Approx. 150 g 

Compliant with RoHS directives 

 

Exclusive AC adapter RC60G-12D 

[connector shape B type] 

Input voltage 

100 to 240 VAC 50/60 Hz 

*

 

Output voltage 

12 VDC (4 A) 

External dimensions 

53 (W) 

×

 118.4 (D) 

×

 33.5 (H) mm 

Weight 

Approx. 350 g 

Standards 

PSE, UL, CE 

Compliant with RoHS directives 

*

 (A power supply cable for Japanese market included) 

If the power supply voltage exceeds 100 V, provide a power supply 
cable that complies with the laws, regulations, and safety standards 
of the country or region where it is being used. 

 

During Charging 

 

Simple Voltage Check 

 Red 

Green 

 

 Red 

Green 

Charging 

U

Flashing  

 

Normal 
voltage 

{

 Lit 

{

Lit 

Charging 
completed 

 

{

 Lit 

 

Low voltage

{

 Lit 

U

Flashing

Temperature 
standing by 

{

 Lit   

 

 

Error 

U

Flashing 

U

Flashing 

 

To AC power outlet 

QCA-W5 

Exclusive AC adapter 

RC60G-12D 

Output side 

Input side 

To MP-W5P power connector 