Summary of Contents for AQUA IONIC

Page 1: ... di 24 AQUA IONIC USER S AND MAINTENANCE MANUAL y Distributed b 37 Tannery Lane 06 08 Tannery House Singapore 347790 Tel 65 6741 2994 Fax 65 6741 2995 S I A T A Asia Pacific Pte Ltd Distributed by www siata com sg ...

Page 2: ...EC and that the following harmonized standards have been applied EN 50081 1 Generic Emission Standard Part 1 residential commercial and light industrial premises EN 50082 1 Generic Immunity Standard Part 1 residential commercial and light industrial premises EN 60742 Directions concerning isolation and security trasformers S I A T A S r l has a quality system in accordance with the requirements of...

Page 3: ... Powering on 10 6 2 Working 10 6 2 1 Auto Set Point 11 6 2 2 Auto Volume 12 6 2 3 Auto Set Point Auto Volume 12 6 2 4 Manual 12 6 2 5 Auto Set point Manual 12 6 2 6 Auto Volume Manual 13 6 3 Checking the regeneration efficiency 13 6 4 Programming 14 6 5 Starting operations 15 6 6 Managing the volume 15 6 7 Installing the probe 16 6 8 Connections 17 6 8 1 Connection of this version to 3 DIN sockets...

Page 4: ...onic is provided with an eeprom memory where the programming is stored and of a buffer battery allowing to keep the working parameters in the memory in the event of a supply voltage failure Aqua Ionic as well as all the other SIATA controllers is compliant with the EEC Directives and is built in the SIATA factory in Montespertoli Florence Italy working with the Quality System certified according t...

Page 5: ...n during programming when setting the set point intervention time During operation it illuminates to indicate an alarm condition EXT ALARM It is on when the inhibition signal is present AUTO SET POINT It is on when the regeneration must start because water is not good AUTO VOLUME It is on when the regeneration must start because of exhausted volume MANUAL It is on when the regeneration must not st...

Page 6: ...t allows to increase the digit blinking on the display When pressed during operation it allows to display the residual volume SELECT It allows to change the regeneration start mode MAN REGEN It allows to activate the regeneration manually RESET During programming it allows to quit without saving the parameter being modified when the key is pressed During regeneration it ends it HIDDEN KEY Placed b...

Page 7: ...e lot number SN 110 98 the serial number with reference to the code In particular the controller code is composed as follows AI 7 02 05 Controller version assigned by the Technical Office for customizations 05 standard Typology of the electric connections 02 DIN sockets Number of drivers 7 7 drivers Family to which the controller belongs AI Aqua Ionic Fig 2 Fig 2 ...

Page 8: ...C relative humidity within 30 and 95 5 2 Installation The controller installation must be performed by qualified technical staff the installation procedures must be performed when the device is off power The device consists in an ABS case closed on front by a cover blocked with 4 screws As an optional a transparent cover is available that can be used as a keyboard protection The controller is supp...

Page 9: ... battery voltage using a multimeter If the measured voltage is less than 3 2 Vdc replace the battery with the spare part code 867 The following servicing operations must always be performed when the controller is off power In case of replacement of the electronic board only and each time you operate on the open case please avoid as much as possible touching the components and the welded parts with...

Page 10: ...icate that the foreseen conditions have been reached Manual The regeneration starts only when pressing the proper key Auto Set Point Manual The timer performs the checks requested by the Auto Set point mode but it is not able to perform the regeneration in the automatic mode Auto Volume Manual The timer performs the checks requested by the Auto Volume mode but it is not able to perform the regener...

Page 11: ...illuminates The display is still indicating the conductivity 0 0 5 0 Pressure of the Manual Regen key during operation The regeneration cycle starts even if the controller is inhibited see previous point 1 C 2 6 6 2 1 Auto Set Point When Aqua Ionic is programmed in the Auto Set Point mode this condition must be confirmed by the illumination of the corresponding LED on the panel there is a comparis...

Page 12: ...to Set Point Auto Volume mode both LEDs on the panel are on both checks indicated in par 6 2 1 and 6 2 2 are carried out The regeneration is activated by the check which as first satisfies the conditions required for the cycle to be started 6 2 4 Manual When Aqua Ionic is programmed in the Manual mode this condition must be confirmed by the corresponding LED on the panel the regeneration can be ac...

Page 13: ...LED illuminates on the panel If the value read by the probe is lower than the set point value the last cycle phase is terminated before the expiration of the set time in order not to waste water The Int Alarm LED goes out and the controller will immediately start working If on the contrary the value read by the probe remains above the set point value for the whole duration of the last phase of the...

Page 14: ... C 0 0 The stop of the regenerative cycle second phase 10 PROG MODE 3 C 0 0 The stop of the regenerative cycle third phase 11 PROG MODE 4 C 0 0 The stop of the regenerative cycle fourth phase 12 PROG MODE 5 C 0 0 The stop of the regenerative cycle fifth phase 13 PROG MODE 6 C 0 0 The stop of the regenerative cycle sixth phase 14 PROG MODE 7 C 0 0 The stop of the regenerative cycle seventh phase 15...

Page 15: ...s the Reset key or to perform a regeneration in order to load the new parameters into the memory 6 6 Managing the volume Steps 3 and 4 of tab 3 describe how to program the treatable volume Using the SIATA Hall effect liter counter the value of the divider AA14 step 5 tab 3 must be set to 14 which means that the available volume is reduced in a not adjustable way by one liter every 14 impulses issu...

Page 16: ...te that because of the Reed counters characteristics we recommend not to use 1imp 1m3 or similar counters 6 7 Installing the probe The conductivity probe is the most important element of Aqua Ionic and its installation must be performed with the highest care A screened cable is always the best choice to connect the controller to the probe This choice is compulsory when the distance between the con...

Page 17: ...xample it is the cycle end impulse Please refer to the table of par 6 8 1 to learn which signals are issued by the controller in the Open Collector mode The maximum relay absorbency for the trip coil excitation must be 20mA Here below follow the codes of a few relays that can be used to this purpose all of them with a trip coil to be supplied with 12 Vcd Manufacturer Model OMRON G5V 1 12Vdc TAKAMI...

Page 18: ...12 Vdc voltage DIN A 1 4 Inhibition signal input when closed DIN A 2 5 Output of the Cycle End Impulse in the Open Collector mode DIN B 4 2 Input of the Remote start signal when closed DIN B 3 2 Input of the regeneration quality control activation signal DIN C 1 4 Output of the Set Point signal in the Open Collector mode DIN C 3 4 Output of the Impulse During Regeneration signal in the Open Collec...

Page 19: ...at the wires be properly inserted in the 7 pole connector The controller is blocked If you use the side DIN socket check for any short circuited terminals in the connector cap Follow instructions given in par 6 8 The motor does not stop at the limit stop Damages in the plastic components Open the case and check whether the plastic components supporting the micro switch are integer Fig 10 The micro...

Page 20: ...Aqua Ionic 20 di 24 Fig 10 clearly shows the micro switch its block and command mechanical details and the terminals for connection to the controller Fig 10 Seeger ...

Page 21: ...otation Please contact the SIATA sales department for further information about the performances that can be obtained with such a modification 4 The plug shaped transformer item 6 can be provided in two ways chlorine timer transformer code 95 STC1 and non chlorine timer transformer code 95 STD The explicit variants concern only the timers with external drivers attachment DA0189 which in the table ...

Page 22: ...aped transformer 230V 12 V 6 V CHLORINE 95 STC1 7 Ratiomotor 94 R7 8 Timer case kit 81 KIT 9 7 pole connector 93 7 10 Timer supply cable lock 90 11 Micro switch wire 97 12 External cam kit 2221 2 13 Micro switch blocking plate 88 A 14 Microswitch 92 F 15 Microswitch holder 88 16 Aqua Ionic electronic board kit 892 K 17 Cover blocking screw 120 18 Timer case transparent cover 82 19 Stop ring on pow...

Page 23: ... 17 M A S C H E R I N A POS 16 SOSTITUISCE S r l CODICE DENOMINAZIONE SCALA FIRMA POS 18 POS 15 POS 11 POS 14 POS 13 POS 19 POS 7 POS 12 POS 9 POS 10 POS 8 POS 4 POS 3 POS 6 POS 5 POS 2 POS 1 SCHEMA GENERALE TIMER ELETTRONICO CON N PILOTI ESTERNI Foglio 1 di 1 DA0189 Ing P Meozzi 08 A POS 20 POS 21 ...

Page 24: ...GRUPPO REVISIONE Foglio 1 di 1 SCHEMA GENERALE TIMER ELETTRONICO CON CAMMA 132 DA0191 Ing P Meozzi 08 A POS 13 POS 18 POS 15 POS 11 POS 14 POS 7 POS 9 POS 8 POS 10 POS 6 POS 21 POS 20 POS 19 POS 22 y Distributed b 37 Tannery Lane 06 08 Tannery House Singapore 347790 Tel 65 6741 2994 Fax 65 6741 2995 S I A T A Asia Pacific Pte Ltd Distributed by www siata com sg ...