6 – INSTRUCTIONS FOR USE
6.1 – Powering on
Aqua Ionic
is not provided
with power switches. Powering on is obtained by connecting the power
transformer to the outlet.
6.2 – Working
After powering on, the display placed on the front panel will display the conductivity value read by
the probe.
The regeneration starting modalities are the following:
Auto Set Point
The regeneration starts at the expiration of the programmed delay time that
begins to be counted when the conductivity value read by the probe exceeds the
programmed threshold limit.
Auto Volume
Immediate start when the available volume is exhausted.
Auto Set Point
+ Auto Volume
The timer performs both the above mentioned checks and will activate the
regeneration as soon as either of the two checks will indicate that the foreseen
conditions have been reached.
Manual
The regeneration starts only when pressing the proper key.
Auto Set Point
+ Manual
The timer performs the checks requested by the Auto Set point mode, but it is not
able to perform the regeneration in the automatic mode.
Auto Volume +
Manual
The timer performs the checks requested by the Auto Volume mode, but it is not
able to perform the regeneration in the automatic mode.
Event
What happens
Display
Powering on
The display shows the conductivity value read by
the probe.
0 0 5 0
Start of operation
At the end of a regeneration, or pressing the reset
key, the working parameters are restored with the
programmed values. The display shows the
conductivity.
0 0 5 0
Exhausting volume
The impulses issued by the counter allow to
decrease the treatable volume. The display is still
showing the conductivity.
0 0 5 0
The regeneration will start when the volume
reaches value 0 and the timer is programmed in the
Auto Volume mode.
1 C 2 6