7 – TROUBLESHOOTING
Here follow some basic operations that will help solving those little problems that could arise when
using the
Aqua Ionic
.
As a general rule, if the suggested remedies do not give any results and independently from the type
of controller, we suggest to check the anomaly by replacing only the electronic board with a new
one or anyway with one that is certainly in a good state (obviously to the extent of your
possibilities). It is important to be able to identify whether the cause of the malfunction is to be
found in electronics, mechanic part, or the harness wiring. Replacing the electronic board may be
already a precious help to identify the real cause of the defect. If our suggestions are not sufficient
to solve your problems, please contact the SIATA assistance service.
DEFECT
POSSIBLE CAUSE
REMEDY
The
controller
does not power
on.
Failure of the supply outlet.
Failure of the transformer plug.
Failure of the transformer.
Connect any other kind of device to the same outlet
and the controller to another outlet.
Problem in the cable connection. Open the case and check that the wires be properly
inserted in the 7-pole connector.
The controller is blocked.
If you use the side DIN socket, check for any short-
circuited terminals in the connector cap.
Follow instructions given in par. 6.8.
The motor does not stop at the
limit stop.
Damages in the plastic
components.
Open the case and check whether the plastic
components supporting the micro switch are integer
(Fig. 10).
The micro switch is damaged.
Open the case and check whether (Fig. 10):
the micro switch is integer;
it is placed correctly;
the terminals are placed correctly;
the connection wires are integer;
the micro switch starting lever is integer.
The cam is out of place.
Open the case (Fig. 10) and check that the metal
seeger holding the cam be integer and correctly
placed in its casing.
Turn the cam with your hand to check whether it
activates the micro switch lever.
The
controller
does not
perform regeneration.
The controller is not correctly
programmed.
Check that the programming has been performed
correctly and that the regeneration start corresponds
to the really necessary one.
The controller is inhibited.
If you are using the DIN socket (Fig. 9), check for
any short-circuited terminals in the connector cap.
Wrong parameters are
displayed.
The controller is out of program. Reset the controller following instructions given in
par. 6.8.