4.

 

Installation

 

 

Do

 

not

 

open

 

or

 

alter

 

any

 

part

 

of

 

the

 

product

 

which

 

would

 

lead

 

to

 

malfunction

 

and

 

irrecoverable

 

damage.

 

It

 

will

 

also

 

forfeit

 

the

 

terms

 

of

 

the

 

warranty

 

and

 

cause

 

liability.

 

The

 

product

 

at

 

the

 

time

 

of

 

shipment

 

is

 

fully

 

inspected

 

for

 

its

 

quality

 

and

 

meets

 

all

 

safety

 

requirements.

 

Additional

 

safety

 

measures

 

during

 

the

 

installation

 

should

 

be

 

applied.

 

This

 

includes,

 

but

 

is

 

not

 

limited

 

to

 

the

 

leakage

 

verification

 

procedures,

 

standard

 

EDS

 

(electrostatic

 

discharge)

 

precautions,

 

DC

 

voltage

 

precautions.

 

Other

 

tasks

 

such

 

as

 

calibration,

 

part

 

replacement,

 

repair,

 

and

 

maintenance

 

must

 

only

 

be

 

performed

 

by

 

trained

 

personnel.

 

Upon

 

requests,

 

the

 

manufacturer

 

will

 

provide

 

necessary

 

technical

 

support

 

and/or

 

training

 

of

 

the

 

personnel.

 

There

 

are

 

no

 

preferred

 

directions

 

for

 

the

 

installation.

 

Flow

 

direction

 

should

 

be

 

aligned

 

with

 

the

 

arrow

 

mark

 

on

 

the

 

meter

 

body.

 

If

 

the

 

flowing

 

fluid

 

may

 

have

 

particles

 

or

 

debris,

 

a

 

filter

 

is

 

strongly

 

recommended

 

to

 

be

 

installed

 

upstream

 

of

 

the

 

meter.

  

Please

 

follow

 

the

 

following

 

steps

 

to

 

complete

 

the

 

installation:

 

a)

 

Upon

 

opening

 

the

 

package,

 

the

 

product's

 

physical

 

integrity

 

should

 

be

 

inspected

 

to

 

ensure

 

no

 

visual

 

damage.

 

 

b)

 

Before

 

installation

 

of

 

the

 

product,

 

please

 

ensure

 

that

 

the

 

pipe

 

debris

 

or

 

particles

 

or

 

any

 

other

 

foreign

 

materials

 

are

 

completed

 

removed.

   

c)

  

Close

 

the

 

meter

 

valve

 

completely.

 

d)

  

During

 

installation,

 

please

 

make

 

sure

 

no

 

foreign

 

materials

 

(such

 

as

 

water,

 

oil,

 

dirt,

 

particles,

 

etc.)

 

entering

 

into

 

the

 

installation

 

pipeline.

 

 

e)

 

Connect

 

electrical

 

wires

 

per

 

the

 

wire

 

definition

 

in

 

Table

 

3.2.

  

Please

 

be

 

sure

 

of

 

the

 

power

 

supply

 

range

 

(i.e.,

 

8

 

~

 

24

 

VDC)

 

and

 

power

 

supply

 

polarization.

  

If

 

an

 

adapter

 

other

 

than

 

the

 

one

 

supplied

 

by

 

the

 

manufacturer,

 

make

 

sure

 

the

 

adapter

 

meets

 

industrial

 

standards

 

and

 

has

 

all

 

safety

 

certifications.

  

f)

 

For

 

the

 

data

 

communication

 

wire

 

connection,

 

please

 

follow

 

the

 

description

 

in

 

Table

 

3.2

 

and

 

make

 

sure

 

that

 

the

 

wires

 

are

 

correctly

 

connected

 

to

 

the

 

proper

 

ports

 

on

 

your

 

data

 

device/equipment.

   

Please

 

make

 

sure

 

the

 

data

 

cable

 

meets

 

industrial

 

standards

 

with

 

proper

 

shielding.

   

g)

  

Once

 

the

 

external

 

power

 

is

 

successfully

 

connected,

 

the

 

LED

 

should

 

be

 

lighted

 

up

 

with

 

the

 

proper

 

information

 

displayed

 

works

 

correctly.

 

h)

 

Slowly

 

open

 

the

 

valve(s)

 

of

 

the

 

gas

 

supply

 

if

 

any,

 

upstream

 

or

 

downstream,

 

or

 

both

 

of

 

the

 

pipeline.

 

And

 

then

 

slowly

 

open

 

the

 

valve

 

of

 

the

 

meter,

 

the

 

meter

 

should

 

then

 

start

 

to

 

measure

 

the

 

flow

 

in

 

the

 

pipeline.

   

Note:

 

because

 

the

 

meter

 

has

 

a

 

large

 

dynamical

 

measurement

 

range,

 

it

 

Summary of Contents for FS4701

Page 1: ...Gas Mass Flow Meter VB 2 Model MF4700...

Page 2: ...Issue date 2021 06 Revision VB 2 Siargo Ltd 3100 De La Cruz Boulevard Suite 210 Santa Clara CA 95054 USA Tel 1 408 969 0368 Email info siargo com Copyright 2021 by Siargo Ltd Siargo Ltd and its subsid...

Page 3: ...vibration environment Use this product according to the specified parameters Only the trained or qualified personnel shall be allowed to perform product services Be cautious for the electrical safety...

Page 4: ...akage 12 5 3 Power the meter and digital data connection 12 5 4 Meter display and MENU descriptions 13 5 4 1 Meter display and function keys 13 5 4 2 MENU function input sequence 14 5 4 3 Detailed des...

Page 5: ...8 2 Precautions for the best performance of the product 27 8 2 1 Comparison with a third party reference meter 27 8 2 2 Particle contamination and fluidic cleanness 28 8 2 3 Apply to a different gas...

Page 6: ...massflow meters are designed for general purpose precise industrialgas processing monitor or control The meter series cover a wide dynamic flow range with a working pressure rating of up to 1 0 MPa an...

Page 7: ...t display per your actual order The power adapter and or data cable as shown below may also be found according to your actual order Figure 2 1 MF4700 flow meter Figure 2 2 FS4700 flow meter Figure 2 3...

Page 8: ...The standard cable has an AMPMODU MTE 5 positions compatible connector with a length of 0 5 meters Figure 3 2 MF4700 connection and cable Wire Color Definition 1 Blue RS485B 2 Green Analog output 3 R...

Page 9: ...dimensions Figure 3 3 FS MF4701 03 08 dimensions Figure 3 4 MF4712 dimensions Model N H1 H2 H3 FS4701 03 NPT 1 8 BSPT 1 8 39 0 20 0 10 0 MF4701 03 NPT 1 8 BSPT 1 8 43 0 24 0 12 0 FS4708 NPT 3 8 BSPT...

Page 10: ...www Siargo com MF4700 User Manual 9 P a g e Figure 3 5 MF4719 dimensions...

Page 11: ...ity should be inspected to ensure no visual damage b Before installation of the product please ensure that the pipe debris or particles or any other foreign materials are completed removed c Close the...

Page 12: ...here is no leakage or flow h This will conclude the installation Cautions a Don t alter any parts of the product b Ensure the electrical connection is properly done per the instructions c Make sure no...

Page 13: ...ed functions For the best performance of the product it is advised that the gas to be measured must be clean and free of particles or other foreign materials 5 2 Check the leakage Check gas leakage be...

Page 14: ...flow rates below the lower limit If both LEDs are flashing the displayed values are incorrect Once the power is supplied and no abnormal issues are observed the meter is ready to perform the measurem...

Page 15: ...easurement main display press the three MEMU keys it will allow the user to perform a variety of settings of the product The following graph details the key sequence for each function and some detaile...

Page 16: ...fault value is 100 means of 100 full scale 7 0 110 Set the lower flow rate alarm Available 0 110 means of 0 110 full scale Default value is 0 means of 0 full scale 8 0 1 2 3 Set the display decimal 9...

Page 17: ...ibrate the offset Sometimes or after a long time of use i e over 1 year of usage the sensor surface could have a thin deposit from the environment if the gas is not super clean Depending on the actual...

Page 18: ...function allows the user to set a maximum allowable flow rate above which an alarm will be triggered with a flashing screen 7 Set the lower flow rate alarm This function allows the user to set a mini...

Page 19: ...alue of the GCF is 1000 1 000 For example if one wants to alter the standard temperature to 0 C the factor can be calculated using the gas equation PV T constant GCF 1000 x V new V 20 C T o C T 20 C 1...

Page 20: ...ble 3 2 for cable connection 5 5 1 Hardware connection The RS485 hardware layer is TIA EIA 485 A as illustrated below In this configuration the product MF4700 is a slave Figure 5 3 RS485 hardware 5 5...

Page 21: ...egister length of data and the data themselves CRC CRC verification code The low byte is followed by the high byte For example a 16 bit CRC is divided into BYTE_H and BYTE_L In the framing the BYTE_L...

Page 22: ...r 1 Totalizer or accumulated flow rate R 0x0004 0x0005 40005 0x0005 Totalizer 2 Totalizer or accumulated flow rate R 0x0004 0x0006 40005 0x0005 Baud rate Communication baud rate R W 0x0015 40022 0x001...

Page 23: ...is SLPM accumulated flow rate unit is Nm3 Value type UINT 32 UNIT 16 Notes A1 value 0x0004 65536 value 0x0005 A2 value 0x0006 Totalizer or accumulated flow rate A1 1000 A2 1000 e g for a totalizer or...

Page 24: ...flow rate value value 0x0033 65536 value 0x0034 1000 Offset reset 0x0027 Write Y Read N Description Reset or calibrate the offset Value type UINT 16 fixed value 0xAA55 Notes Send the fixed value 0xAA...

Page 25: ...s output The meter is calibrated to 110 of the specified full scale flow rate The typical analog output is indicated below This over range applies to both analog and digital output Table 5 7 MF4700 an...

Page 26: ...and customer support The sales offices and the sales distributors representatives are listed at the end of this document For small quantities the order can be placed either through the Siargo website...

Page 27: ...no condensation RH Power supply 8 24 50 mA Vdc Digital output RS485 Modbus half duplex Voltage Electrical connector AMPMODU MTE 5 positions MENU access 3 key front face keyboard digital Display Insta...

Page 28: ...environmental parameter alternations Please refer to the company s US patents and other publications made available to the public for additional information 8 2 Precautions for the best performance o...

Page 29: ...portant to ensure the applied flow medium will be clean and dry If any contamination is suspected please allow experienced technical personnel to have it checked and re conditioned Do not use a foreig...

Page 30: ...n Power regulator failure Return to factory Sensor failure Return to factory Large errors or unexpected flow rate Particles fluid type Check system Erroneous or large noise Vibration unstable flow Che...

Page 31: ...stallation etc other consequential or indirect damages of any kind To the extent permitted by law the exclusive remedy of the user or purchaser and the limit of Siargo s liability for any and all loss...

Page 32: ...r dismantled for whatever reasons 4 Products that have been subject to working conditions beyond the technical specification as described by this manual or related datasheet published by the manufactu...

Page 33: ...d to your request in a timely fashion and will work with you toward your complete satisfaction Customer service and all orders should be addressed to Siargo Ltd 3100 De La Cruz Boulevard Suite 210 San...

Page 34: ...for further analysis It can read from up to 128 sensors with the RS485 interface in serial For further information and purchase of the evaluation kit please contact the manufacturer or the sales repre...

Page 35: ...MF4700 User Manual 34 P a g e Appendix II Document history Revision B 2 June 2021 Corrections Revision B 1 March 2021 Reformat corrections add the evaluation kit Revision A 2 July 2019 Update the MENU...

Reviews: