background image

 

Manual_UK_K_K_rev. 1_10_2013   

 

 

 

 

 

 

pag. 12 

 
 
 
 
 
 

DESCRIPTION of PATIO-HEATERS 

 
 

SIABS  patio-heaters  are  designed  and  built  with  attention  to  detail,  a  lot  of  attention  to 
reliability  and  giving  importance  to  design:  they  have  a  reflecting  steel  structure,  panels  of 
bottle  compartment  can  be  customized  with  different  colors,  safety  grids  on  all  sides,  high 
efficiency and long life, burner  made in metallic fiber, heating element with flame and safety 
glass (model 

K

ALIENTE), adjustable feet. 

 
Installation is easy and in no time the heaters are ready for operation: you just have to place 
and connect the gas cylinder after removing the front panel (with slot). 
 
 
All heaters are controlled and calibrated to the correct pressure values (depending on the type 
of gas and the country of destination), and then tested in the company by SIABS personal. On 
each  heater  you  will  find  a  technical  data  plate  (see  page  6  of  this  manual),  according  to 
norms, to which the installer has to refer for any future action. 
 
 
SIABS patio-heaters are certified and approved for use with natural gas or LPG; the burner has 
been  subjected  to  strict  tests  (with  gas  operating  limits)  in  the  laboratories  of  our  approval 
authority KIWA Gastec – Italy

.

 

 
 

GET READY TO WORKING – SUGGESTIONS 

 
 

Below you will find 

IMPORTANT

 suggestions:  

 

SIABS patio-heaters can be supplied: 

 

fully pre-assembled:

 you have only to provide the gas bottle and the pressure 

 

 

reduction kit (flexible pipe + pressure reducer, different from country to country) 

 

to be assembled on site:

 burner is fully mounted and tested in our factory, 

 

 

all other components are easy to be assembled, following specific instruction 

 

pay particular attention 

during unloading and all handling operations

 of the heater 

due to the fragility of the glass tube (model 

K

ALIENTE) 

 

open the carton in a horizontal position on a stable surface or on the floor, then lifting 
the product with the help of a second person (weight approx. 45 kg) 

 

cut the clamp that fixes the glass tube

 (model 

K

ALIENTE) before start-up 

 

verify  that  the  feed  pipe  and  the  gas  coupling  installed  are  in  compliance  with  the 
regulations in force in the country of use 

 

in  case  of  gas  smell  while  patio-heater  is  running, 

switch  off  it  immediately  and 

verify any gas leaks before using it again

: you can use soapy water or equivalent 

 

when  replacing  the  LPG  gas  bottle,  you  can  use  soapy  water  or  equivalent  to  check 
connections and fittings for leaks 

 

IMPORTANT:

 at the first ignition is likely to happen a delay in turning the pilot flame; 

the  situation  is  normal,  and  due  to  the  fact  that  the  circuit  has  gas  inside  air  to  be 
disposed of; the inconvenience will disappear with two or three ignitions. To avoid any 
darting flames, let about 2 minutes between each ignition procedure and the next. This 
situation could be repeated when replacing a gas bottle: proceed as above. 

Summary of Contents for KALIENTE E

Page 1: ...d MAINTENANCE Patio heaters models KALIENTE E M and SOLFLAME E M models KALOR M and SOLEIL M manual start up SIABS S r l ITALY Phone 39 02 90384081 E mail commerciale siabs it via Del Lavoro 7 Fax 39...

Page 2: ...t ready to working suggestions 12 Put in operation and First Start up 13 17 position of heater handling and gas bottle positioning 13 and 14 suggested gas bottle 14 start up 15 17 Safety devices 18 Ma...

Page 3: ...e appliance must be installed only in premises with adequate ventilation installation should be done in accordance with the Regulations in force in the country of destination to the state of art follo...

Page 4: ...nd modification kits every time the gas bottle is replaced check that gasket of gas regulator is in correct position and works as requested you should check periodically the flexible gas pipe to check...

Page 5: ...defects The guarantee does not cover problems due to carelessness incorrect setting misuse of the appliance or fortuitous accidents and not dependent on imperfection processing or defective materials...

Page 6: ...echnical data do not remove placed inside the gas bottle compartment on the burner cover Apparatus type A1 Plate label example patio heater KALIENTE Electronic gas type G31 propane Essential features...

Page 7: ...20 mbar G31 37 mbar RO C II 2H3 G20 G25 20 25 mbar G30 G31 28 30 37 mbar HU II 2H3B P G20 25 mbar G30 G31 30 mbar PL II 2E3B P G20 20 mbar G30 G31 37 mbar PL II 2E3P G20 20 mbar G31 37 mbar CH II 2H3...

Page 8: ...I II 2H3P G20 20 mbar G31 37 mbar RO C II 2H3 G20 G25 20 25 mbar G30 G31 28 30 37 mbar HU II 2H3B P G20 25 mbar G30 G31 30 mbar PL II 2E3B P G20 20 mbar G30 G31 37 mbar PL II 2E3P G20 20 mbar G31 37 m...

Page 9: ...g 9 OVERALL DIMENSIONS patio heaters KALIENTE KALOR SOLFLAME SOLEIL NOTE we recommend to make use of the 4 adjustable feet to ensure always optimal vertical position and avoid floor surface damage MIN...

Page 10: ...By minimum distance of installation we mean the distance to be kept between the patio heater and any component potentially flammable We recommend to keep at least 0 5 mt between the cover top of the...

Page 11: ...to give comfort in all spaces which need complete or partial heating SIABS patio heaters must be installed in partly protected areas it is not designed to be subject to direct action of atmospheric a...

Page 12: ...fully pre assembled you have only to provide the gas bottle and the pressure reduction kit flexible pipe pressure reducer different from country to country to be assembled on site burner is fully mou...

Page 13: ...1 HANDLING for all movements of the patio heater for secure and easier handling we recommend to use only SIABS device for transport handling optional named kit for transport fixing it to the lower pa...

Page 14: ...r the fitting of the pressure reducer on tap of gas bottle and slowly open the tap of the gas bottle Picture 8 Picture 7 Picture 8 check with soapy water or equivalent material losses on the connectio...

Page 15: ...e detection electrode will give positive input for total opening of the gas valve and then turning on the heater takes place one remote can manage more heaters on off level of power To switch off pres...

Page 16: ...conds leave the knob and verify that the pilot device stays on repeat the operation if the pilot device goes out Picture 11 NOTE to switch off turn the knob to position 0 ZERO Picture 11 MANUAL VERSIO...

Page 17: ...case you want to enjoy a different level of comfort or fit it to different external temperatures MANUAL version with pilot device on turn the knob towards MIN or MAX as on the plate Picture 11 until y...

Page 18: ...id any leakage of gas The thermocouple placed on the ignition pilot detects the flame and locks the gas circuit if the heater turns off due to lack of gas or accidentally plus there is also a mechanic...

Page 19: ...ould become necessary to replace the glass tube blackening important after a few years or accidental breakage proceed as follows wait until the patio heater is cold in all its parts remove upper cap 4...

Page 20: ...to change type of gas e g from LPG to natural gas it is COMPULSORY to change the PRESSURE STABILIZER only for manual start up version and to change the plate label with technical data and place one w...

Page 21: ...urns on then it C1 Fault with thermocouple C1 Replace thermocouple turns off as soon as you release the gas tap D No spark at pilot start up D1 Spark electrode damaged D1 Replace electrode D2 Spark ca...

Page 22: ...ocouple of the flame or work C2 Fault with remote control C2 Replace remore control partially C3 Fault with command control C3 Replace command control D No spark at pilot start up D1 Fault with spark...

Page 23: ...ocked A4 Replace anti tilt sensor B The burner turns on then it B1 Fault with thermocouple B1 Replace thermocouple turns off as soon as you release the tap version C No spark at C1 Spark electrode dam...

Page 24: ...02EKAL12 ____ cables DC 0104EKAL12 ____ battery box 0105EKAL12 ____ remote control 0103EKAL12 ____ Patio heater KALIENTE SOLFLAME MANUAL glass pipe 001TOBF1200 ____ pilot complete 440 1221 13 ____ ele...

Page 25: ...Manual_UK_K_K_rev 1_10_2013 pag 25 CE certificate...

Page 26: ...Manual_UK_K_K_rev 1_10_2013 pag 26 Service sheet DATE and STAMP OPERATION NOTE DATE and STAMP OPERATION NOTE DATE and STAMP OPERATION NOTE DATE and STAMP OPERATION NOTE...

Page 27: ...to appropriate separate collection centres of electric and electronic waste or return it to the dealer when purchasing a new device to be equivalent in terms of one to one The proper differentiated c...

Page 28: ...rezzo MI ITALIA _______________________________________________________________ To contact us Phone 39 02 90384081 Fax 39 02 9029538 E mail commerciale siabs it Web page www siabs com Continuous devel...

Reviews: