Manual_UK_K_K_rev. 1_10_2013
pag. 18
SAFETY DEVICES
on PATIO-HEATERS
N.B. –
SIABS patio-heaters are delivered ready for operation, already set according to the
type of gas and the country of destination, and equipped with a pressure reducer:
does not
require additional settings, or other accessories
;
shall not be permitted any change
in burner pressure running: guarantee will not be valid anymore.
We are at your
disposal for any questions or requests.
If the pilot flame keeps going out, see system faults (pages 19 to 22 – TROUBLE SHOOTING)
and follow the instructions; if for any reason the heater turns off, the thermocouple placed on
the pilot ensures safety: thermocouple acts quickly on the valve to avoid any leakage of gas.
The thermocouple placed on the ignition pilot detects the flame, and locks the gas circuit if the
heater turns off due to lack of gas or accidentally; plus, there is also a mechanical device
called ANTI TILT (anti rollover), that automatically stops gas leakage by turning off the burner,
when the heater is tilted or occurs an accidental rollover. In this type of heaters that safety is
a key and expressly required by law.
To turn on the heater again, we must repeat the normal start-up procedure (see page 15 -
START-UP). For cases of accidental switching off or empty gas bottle, repeat the ignition
procedure, letting few minutes from the previous year.
N.B. – avoid consecutive ignition attempts
: if the heater has problems in this regard,
check that all the operations required above are fulfilled and executed in a positive way; then,
in case of negative result, contact the manufacturer.