35
User Manual
6. Frequently Asked Questions
6.1
How can I disconnect the cables from the ES502 in case
I need to do so for the installation?
♦
Open the ES502 box unscrewing the four screws (see the following
figure).
Rubber Gasket
Fig. 6.1 - The BB 50/200 (I)
♦
Once the screws are removed, pull out the panel and the Printed Circuit
Board (PCB). Unscrew the cables from the PCB.
Panel
PCB
GPS
Chart Plotter
cable
Power & I/O
cable
Cap
Grommet
Cap
Fig. 6.1a - The BB 50/200 (II)
♦
Wire the cables as needed.
♦
Reconnect the cables to the PCB (see the Fig. 4.5 for reference).
♦
Push the panel towards the case (be sure to have well positioned the
rubber gasket). Close the ES502 box screwing the four screws.