Shure Incorporated
23/63
◦
◦
◦
◦
◦
◦
DANTE VERSIONS
REV
FW
HW
BOOT
USER
CAP
Transmitter IR Presets
Use the
IR PRESETS receiver menu to quickly configure transmitter settings from the receiver screen. When a sync is per
formed between the receiver and transmitter, the IR PRESETs automatically configure the transmitter. Each parameter has the
default value KEEP, which leaves that setting unaffected by a sync.
Feature
Setting
BP PAD
+0 dB, -12 dB
LOCK
Power, Menu, All, None
RF POWER
10mW=Nm (normal), 1mW=Lo (low), 20mW=Hi (high)
BATT
Alkaline, NiMH, Lithium
BP OFFSET
0 dB to +21 dB (in 3 dB increments)
HH OFFSET
0 dB to +21 dB (in 3 dB increments)
MUTE MODE
OFF, ON
Cust. Group
OFF, ON
Note:
When
Cust. Groups
is set to on, it may take up to 30 seconds to complete an IR sync.
Creating a System Preset
System Presets allow a current receiver setup to be saved and restored. Presets store all receiver settings to provide a quick
way to configure a receiver or switch between several different setups. Up to 4 presets can be stored in receiver memory.
To save the current receiver setup as a new preset:
DEVICE
UTILITIES
>
SYSTEM
RESET
>
SAVE
>
CREATE
NEW
PRESET
Use the control wheel to name the preset, and then press Enter to save.
To recall a saved preset:
DEVICE
UTILITIES
>
SYSTEM
RESET
>
RESTORE
Use the control wheel to select the preset name, and then press Enter.