Shure Incorporated
12/17
Converting LEMO to TA4F
Series
Cable
Con
struc
tion
Electri
cal De
sign
Polari
ty
Re
place
ment
Con
nector
For Use
With
Wiring
Line Art (From Solder Side)
TH53-
LEMO
1.6mm
cable
with 2
con
duc
tors, 2
shield
wires
and
shield
2-Wire
(Com
mon
Source)
Nega
tive
with
re
spect
to
ground
Shure
TQG/
TA4F:
WA430
Termination
Dependent
Shield wire: Ground(1)
Red wire: Audio/
Bias(3)
Blue wire: Not con
nected
8.25kΩ Resistor be
tween pin 2 and 3
Shield: Ground(Shell)
TA5F Wiring for Lectrosonics Bodypacks (Servo Biased Wiring)
Series
Cable
Con
struc
tion
Electri
cal De
sign
Polari
ty
Re
place
ment
Con
nector
For Use
With
Wiring
Line Art (From Solder Side)
TH53-
MTQG
1.6mm
cable
with 2
con
duc
tors, 2
shield
wires
and
shield
3-Wire
(Source
Follow
er)
Posi
tive
with
re
spect
to
ground
WA435
Lectrosonics
TA5F body
packs
Red wire: Bias(3)
Blue wire: Audio(5)
Shield wire: Ground(1)
Shield: Ground(Shell)
Jumper between 2 and
4
TH53-
LEMO,
TH53-
NC
1.6mm
cable
with 2
con
duc
tors, 2
shield
wires
and
shield
2-Wire
(Com
mon
Source)
Nega
tive
with
re
spect
to
ground
WA435
Lectrosonics
TA5F body
packs
Red wire: Audio/
Bias(3)
Blue wire: Not con
nected
Shield wire: Ground(1)
Shield: Ground(Shell)
Jumper between 2 and