Shure Incorporated
19/43
•
•
•
*
If an error occurs when a transmitter is docked in the charger, remove the battery from the transmitter and place directly into the charger. If the error persists,
contact Shure Technical Support.
Important Tips for Care and Storage of Shure Rechargeable Batteries
Proper care and storage of Shure batteries results in reliable performance and ensures a long lifetime.
Always store batteries and transmitters at room temperature
Ideally, batteries should be charged to approximately 40% of capacity for long-term storage
During storage, check batteries every 6 months and recharge to 40% of capacity as needed
Average Charging Times
SBC10-903
Time Charging
Operating Runtime
Capacity
1 hour
1 hour
15%
3 hours
4 hours
50%
5 hours : 30 minutes
>8 hours
100%
SBC203
Time Charging
Operating Runtime
Capacity
30 minutes
1 hour
15%
1 hour : 15 minutes
4 hours
50%
2 hours : 30 minutes
>8 hours
100%
*based on battery with 100% health
Sound Check and Gain Adjustment
Navigate to the receiver's Gain screen to test the transmitter at performance levels. Adjust the gain to keep the audio indicator
within the optimal range. Reduce the gain if there is audible distortion of the audio.