Shure Incorporated
14/25
Limiter
Type
Peak
Threshold
±16
dBu
(at output)
Attack Time
2 ms
Recovery Time
300 ms
Indicator
Lights red when limiting occurs
Input LEDs
Green on channel activation, red at 6
dB
below clipping
Phantom Power
12
V DC
open-circuit through 680
Ω
resistors
Operating Voltage
SCM410
100-120 V AC rated nominal, 50/60
Hz
, 100
mA
(maximum)
SCM410E
220-240 V AC rated nominal, 50/60
Hz
, 50
mA
(maximum)
Mains Inrush Current (230 V AC, SCM410E only)
0.7 A Peak
Temperature Range
Operating Temperature
-7° to 49° C (20° to 120° F)
Storage Temperature
-29° to 74° C (-20° to 165° F)
Dimensions
44 x 219 x 267
mm
(1 ¾ x 8 5/8 x 10 ½ in.), H x W x D
Net Weight
1.75
kg
(3.86
lbs
)
Certifications
SCM410: UL LISTED to UL 60065 and cUL LISTED to CAN/CSAC22.2 No. 60065-3 Canada.
SCM410E: Conforms to applicable European Union Directives. Low Voltage Directive, 2006/95/EC: Certified to EN
60065. Eligible to bear CE marking. Conforms to European EMC Directive 2004/108/EC. Meets Harmonized Stan-
dards EN55103-1:1996 and EN55103-2:1996 for residential (E1) and light industrial (E2) environments.