background image

Shure Incorporated

3/12

Rack- or wall-mountable with Shure URT3 mounting tray (sold separately)

Rack and Wall Mounting

SBC250 can be rack- or wall-mounted using the optional Shure URT3 universal rack tray for added flexibility when 

storing ULXD6 boundary microphones.

When mounting to a rack, position the rotatable ears on the URT3 with the 

holes facing forward

For mounting to a wall, rotate the ears so the holes are flush with the surface

Caution:

 When mounted on the wall, insert and remove ULXD6 boundary microphones vertically to avoid damag­

ing the USB connector

More Information Available Online

A comprehensive online user guide is available at pubs.shure.com (http://pubs.shure.com).

Summary of Contents for SBC250

Page 1: ...eing walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 ONLY USE attachments accessories specified by the manufacturer 12 USE only w...

Page 2: ...factory setting General Description SBC250 networked docking station provides simple charging configuration and storage for either 2 ULXD6 and ULXD8 transmitters Dock transmitters for 15 minutes to g...

Page 3: ...6 boundary microphones When mounting to a rack position the rotatable ears on the URT3 with the holes facing forward For mounting to a wall rotate the ears so the holes are flush with the surface Caut...

Page 4: ...ct to an Ethernet network to enable remote device control and monitoring using Wireless Workbench or oth er control software Ethernet Link Speed LED Amber Off 10 Mbps On 100 Mbps Ethernet Status LED G...

Page 5: ...ace transmitters in charging docks Press and hold reset button for five seconds to restore transmitter factory settings Transmitter mute LEDs flashing ID Button Identifies devices shown in Wireless Wo...

Page 6: ...ork performance If you have multiple devices to manage connect each device to a router or network switch The Ethernet port LEDs on your device will illuminate to indicate network connectivity Verify t...

Page 7: ...otal battery capacity Also shows time remaining to full charge Health Displays health of selected battery as a percentage of the charge capacity of a new battery Charge capacity bat tery life when ful...

Page 8: ...e docking station Check that the docking station is connected to the network and to Wireless Workbench 2 Find the docking station in the inventory and right click to select Properties 3 Select one or...

Page 9: ...suu http www shure com suu Updating Transmitter Firmware with Docking Station 1 Place transmitters on the docking station and check that docking station is connected to the network 2 Launch Shure Upd...

Page 10: ...46 x 7 52 x 2 44in Weight 2 7 kg 5 95 lb Operating Temperature Range 0 C 32 F to 45 C 113 F Storage Temperature Range 29 C 20 F to 74 C 165 F Certifications Meets essential requirements of all applic...

Page 11: ...enclosure for the FCC marking the CE marking the RCM marking the KC marking and the electrical ratings Note EMC conformance testing is based on the use of supplied and recommended cable types The use...

Page 12: ...equipment does cause harm ful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one...