background image

AXT600

Spectrum Manager

Manual for the Shure Axient Spectrum Manager (AXT600).

Version: 4 (2019-L)

Summary of Contents for AXT600

Page 1: ...AXT600 Spectrum Manager Manual for the Shure Axient Spectrum Manager AXT600 Version 4 2019 L...

Page 2: ...ing 9 Network Access Control 10 RF Coordination Wizard 10 All New 10 Update Freqs 10 Update Devices 11 Using All New Wizard Option for System Setup 11 Exclusions 12 Entering Exclusions 12 Event Log 12...

Page 3: ...trum Manager or it can be generated from a computer running Wireless Workbench 6 The on board frequency calculator can be adjusted to avoid specific TV channels frequency ranges or RF signal above a s...

Page 4: ...splitters or distribution amplifiers Front Panel Data display screen Displays Frequency Monitoring status RF plots and signal strength Data display navigation buttons Use to access menu options Menu s...

Page 5: ...tor 100 240 V AC AC power cascade Use IEC extension cables to connect up to 5 rack components to a single AC power source Network speed LED amber Off 10 Mbps On 100 Mbps Ethernet ports Class 1 PoE ena...

Page 6: ...Spectrum Manager to capture scan data and analyze the RF signals used in diversity receiver applica tions If active antennas are used set Antenna DC Power to On To use front mounted antennas Insert t...

Page 7: ...twork Note IP address must be valid to enable networked control Scroll Arrows Indicates additional log entries listed above or below Wizard Sub menu Accesses the following wizard functions All New Upd...

Page 8: ...ts frequency bands for Axient devices controlled by the Spectrum Manager In Use Lists the number of CFL frequencies used by devices controlled by the Spectrum Manager Ready Lists the number of frequen...

Page 9: ...pectrum Manager and receivers to an Ethernet switch Set the IP Mode to Manual for all devices Menu Util Network Use the control wheel to set valid IP addresses for all devices Set the subnet mask for...

Page 10: ...work traffic to pass to the application Check that firewall settings are not blocking network access Network Access Control Access to Shure networked components can be controlled by setting a network...

Page 11: ...tions to coordinate an existing wireless system From the home menu screen choose Wizard and select the All New option The Found Channels screen displays the frequency band and model of devices on the...

Page 12: ...Menu CFL New Exclusions Press the menu button next to the Add option Press the control wheel to highlight TV Start or Stop To exclude a single frequency set the values for the Start frequency and the...

Page 13: ...ed Device ID added Transmitter Tx profile changed Compatible Frequency List CFL CFL cleared New frequency added Frequency deleted Frequency value changed Frequency type changed CFL deployed New CFL ca...

Page 14: ...nd antenna The Listen feature can also be accessed from the CFL Edit menu allowing easy cueing of frequencies that are in use or backups Scanning Performing a spectrum scan creates a plot of RF activi...

Page 15: ...control wheel to position the Cursor at any point in the plot The frequency value and signal strength for the selected point are displayed at the top of the plot Zoom Tool Zoom magnifies RF plot to al...

Page 16: ...s To take advantage of design improvements new versions of the firmware can be uploaded and installed using the Firmware Update Manager tool available in WWB6 software Firmware is available for downlo...

Page 17: ...g frequency range in 64 seconds using 8 scanning modules in parallel Scan time per 60 MHz may be less for specified ranges that allow scanning modules to work in parallel Step Size Maximum Scan Time p...

Page 18: ...1 4 in Output will drive stereo phones Impedance 50 Maximum Signal Level 45 kHz max deviation 1 W 63 Pin Assignments Tip audio Ring audio Sleeve ground Networking Power over Ethernet PoE 50 V DC Class...

Page 19: ...interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or televisi...

Page 20: ...e the apparatus to dripping and splashing DO NOT put objects filled with liquids such as vases on the apparatus The MAINS plug or an appliance coupler shall remain readily operable The airborne noise...

Page 21: ...attached to the nozzle If a sleeve becomes lodged in your ear seek skilled medical assistance to remove the sleeve Damage to the ear may be caused by non professionals attempting to remove the sleeve...

Page 22: ...Compliance Label CAN ICES 3 B NMB 3 B This device contains licence exempt transmitter s receiver s that comply with Innovation Science and Economic Develop ment Canada s licence exempt RSS s Operatio...

Reviews: