Shure Incorporated
4/18
•
•
AXT100 Bodypack Transmitter
①
Infrared (IR) Port
Use for automated transmitter programming. Links transmitter to AXT400 Receiver.
②
Power Button
Hold for 1 second to turn the transmitter on. To power off, press and hold for 2 seconds until
the display reads
Powering Off
.
When editing, acts as an exit button to cancel changes and return to a previous para-
meter or to the main menu screen
In Talk Switch mode, the power button enables push-button audio routing of AXT400
XLR and TRS outputs
③
Power Indicator LED
Green = power on
Red = audio input overload or low battery
Pulsing = pulsing indicates that the transmitter is set to RF mute
④
Microphone Input
4-pin microphone input jack (LEMO version available)
⑤
Arrow Buttons
Use to scroll through menu screens and to change parameter values.
⑥
Set Button
Enables parameter editing. After editing is complete, press to save changes and return to
the main menu screen.
⑦
Shure Rechargeable
Lithium-ion Battery
Delivers up to 8 hours of runtime from a single charge.
⑧
LCD Display
View menu screens and settings. Momentarily press power button to activate backlight.
⑨
Dual-Band Flexible An-
tenna
Covers UHF tuning range and 2.4 GHz ShowLink signal.
⑩
Hardlock Switch
Enables or disables Auto Power Mode locking options.