Shure Incorporated
12/18
3.
4.
Use the control wheel to set the mode to FD-Bodypack.
Use the IR Sync function to Link a transmitter to each channel of the receiver.
Troubleshooting
Input Overload
The
Input Overload
message indicates an excessive signal level at the transmitter input. To prevent overload, reduce the gain
setting.
No
ShowLink
Alert
This alert appears when frequency is edited on a linked transmitter that is beyond the range of an active ShowLink access
point. Choose OK to unlink the transmitter and complete the frequency change, or Cancel to return to the home screen.
Deeply Discharged Batteries
Deep discharge occurs when a battery is discharged to less than 3.0 volts. The battery chargers have a recovery mode de-
signed to restore charge to a deeply discharged battery.
When the charger detects a deeply discharged battery, it automatically enters recovery mode which supplies reduced current
to the battery for up to 30 minutes.
If recovery is successful, the charger will exit recovery mode and charge the battery to capacity. If the battery cannot be
recharged, charging stops and the battery must be replaced.
Specifications
AXT100 Bodypack Transmitter
RF Carrier Frequency Range
470–814 MHz
Working Range
Under typical conditions
150 m ( 500 ft)
Line of Sight, outdoors for a single system
500 m ( 1600 ft)
Audio Frequency Response
40 Hz – 18 kHz (+1, -3 dB)
RF Tuning Step Size
25 kHz
Modulation
45 kHz max. deviation
FM, Audio Reference Companding with pre- and de-emphasis